文献速递美容整形

使用新型模具制作胶合 diced 软骨移植物在亚洲人鼻整形术中进行背侧增高

Dorsal Augmentation Using a Glued Diced Cartilage Graft Fashioned with a Newly Developed Mold in Asian Rhinoplasty.
PubMed 文献 · Plast Reconstr Surg · 2022-07-26

本研究纳入80例使用新型模具制作的胶合 diced 软骨移植物进行背侧增高的患者,66例(82.5%)对手术结果满意,19例(23.8%)出现并发症,8例(10%)行修复手术。三维扫描显示术后1年背侧高度显著增加(p < 0.05)且无背侧增宽,术后3个月至1年背侧高度无显著降低。作者认为该新型模具塑造胶合 diced 软骨似乎是鼻整形术背侧增高的有用技术。

要点

  • 80例患者使用新型模具制作的胶合 diced 软骨移植物行背侧增高,66例(82.5%)满意。
  • 19例(23.8%)出现并发症,8例(10%)行修复手术,1例因移植物吸收修复。
  • 三维扫描显示术后1年背侧高度较术前显著增加(p < 0.05)且无背侧增宽。

核心结论

  • 使用新型模具塑造胶合 diced 软骨似乎是鼻整形术背侧增高的有用技术。

研究设计与样本

  • 研究纳入80例使用模具制作的胶合 diced 软骨移植物行背侧增高的患者,回顾面部照片和医疗记录评估满意度和术后并发症。
  • 对23例有三维扫描影像的患者,测量鼻根和鼻背水平的背侧宽度和高度以探究植入物随时间的变化。
  • 通过比较术后3个月照片与末次随访(术后至少1年)照片评估移植物吸收。

主要发现

  • 66例(82.5%)对手术结果满意。
  • 19例(23.8%)出现并发症,8例(10%)行修复手术,1例因胶合 diced 软骨移植物吸收行修复手术。
  • 三维扫描显示术前与术后1年随访比较,背侧高度显著增加(p < 0.05)且无背侧增宽。
  • 术后3个月与术后1年之间背侧高度无显著降低。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: In dorsal augmentation, costal cartilage can be used in a number of different ways: monobloc, fascia wrapped, or glued diced cartilage grafting (GDCG). The authors developed a mold to make the use of GDCG more convenient. This report describes their experience with GDCG using a novel mold for dorsal augmentation. METHODS: The study involved 80 patients who underwent dorsal augmentation with the molded GDCG. Facial photographs and medical records were reviewed to assess patient satisfaction and postoperative complications. For the 23 patients who had three-dimensional scanned imaging, dorsal widths and dorsal heights at the radix and rhinion levels were measured to investigate changes in the implants over time. Resorption of the graft was assessed comparing the 3-month postoperative photograph with the latest photograph taken at the last follow-up (at least 1 year after the surgery). Serial changes of the dorsum were assessed with three-dimensional scanned images. RESULTS: A total of 66 patients (82.5 percent) were satisfied with their surgical outcomes. Complications were encountered in 19 patients (23.8 percent) and eight revision procedures (10 percent) were performed. One patient underwent revision surgery because of resorption of the GDCG. Analysis using a three-dimensional scanning device showed a significant increment of the dorsal height ( p < 0.05) without dorsal widening when comparing preoperative with 1-year postoperative follow-up data. There were no significant reductions in dorsal height between postoperative 3 months and 1 year. CONCLUSION: The use of a novel mold for shaping glued diced cartilage appears to be a useful technique for dorsal augmentation in rhinoplasty. CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, IV.

来源:Plast Reconstr Surg,查看原文。版权归原作者所有。

引用

  1. Yoo SH, Kim DH, Jang YJ, et al. Dorsal Augmentation Using a Glued Diced Cartilage Graft Fashioned with a Newly Developed Mold in Asian Rhinoplasty. Plast Reconstr Surg. 2022. PMID: 35877941. doi:10.1097/PRS.0000000000009568

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。