激光光生物调节对切除与未切除烧伤创面收缩率的影响:临床前研究的系统评价与Meta分析
该系统评价与Meta分析纳入13项临床前研究(6项定量分析),评估激光光生物调节对切除与未切除烧伤创面收缩率的效果。损伤后两周,激光PBM提高切除烧伤创面的闭合率(SMD=1.34,95%CI 0.41至2.27,I²=0%,低确定性证据);在未切除烧伤中,激光PBM是否增加或降低创面收缩率尚不确定(SMD=1.22,95%CI -0.05至2.49,I²=68%,极低确定性证据)。作者结论认为在动物模型中激光PBM对提高切除烧伤创面收缩率有效,但由于证据确定性低,对效应真实幅度仍存在不确定性,结果应谨慎解读。
要点
- 损伤后两周,激光PBM提高切除烧伤动物模型的创面收缩百分比(SMD=1.34,95%CI 0.41至2.27,低确定性证据)。
- 未切除烧伤中激光PBM对创面收缩率的影响不确定(SMD=1.22,95%CI -0.05至2.49,极低确定性证据)。
- 作者认为动物模型中激光PBM对提高切除烧伤创面收缩率有效,但因证据确定性低,结果应谨慎解读。
核心结论
- 在动物模型中,激光光生物调节可提高切除烧伤创面的收缩率。
- 由于证据确定性低,激光对动物创面收缩效应真实幅度仍存在不确定性,结果应谨慎解读。
研究设计与样本
- 系统评价与Meta分析,检索EMBASE、MEDLINE和LILACS数据库。
- 纳入分析激光光生物调节对烧伤创面收缩效果并评估创面闭合的临床前研究。
- 13项研究纳入定性分析,6项纳入定量分析;使用SYRCLE偏倚风险工具,采用随机效应模型估计合并效应。
主要发现
- 损伤后两周,激光PBM提高切除烧伤创面的收缩百分比(SMD=1.34,95%CI 0.41至2.27,I²=0%,低确定性证据)。
- 未切除烧伤中,激光PBM是否增加或降低创面收缩率尚不确定(SMD=1.22,95%CI -0.05至2.49,I²=68%,极低确定性证据)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 切除烧伤创面分析的证据确定性低。
- 未切除烧伤分析的证据确定性极低,且异质性I²=68%。
- 作者指出由于证据确定性低,对激光影响动物创面收缩效应的真实幅度仍存在不确定性,结果应谨慎解读。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: Laser photobiomodulation (laser PBM) is an effective means of accelerating burn wound contraction, however it is still unclear whether laser PBM produces greater benefit when applied directly to excised and unexcised burn wounds . The aim of this systematic review of preclinical studies was to determine the effectiveness of laser PBM in the wound contraction rate in excised and unexcised burn wounds. MATERIALS AND METHODS: A systematic search was conducted in the EMBASE, MEDLINE and LILACS databases. Preclinical studies were included that analysed the effectiveness of laser PBM in burn wound contraction, and assessed wound closure. The SYRCLE risk of bias tool was used. Random effects models were used to estimate the pooled effect. RESULTS: Thirteen studies were included in the qualitative analysis and six in the quantitative analysis. Two weeks after the lesion, laser PBM favoured the wound contraction percentage, increasing the closure rate in excised burn wounds (SMD= 1.34, CI 95% 0.41 to 2.27, 0.41-2.27, I2=0%, =0%, low certainty of evidence. In unexcised burns, it was uncertain whether laser PBM increased or diminished the wound contraction rate (SMD=1.22(SMD=1.22 CI 95% -0.05 to 2.49, I2=68%; =68%; very low certainty of evidence). CONCLUSIONS: In the animal model, laser PBM is effective in increasing the wound contraction rate in excised burns. However, due to the low certainty of the evidence, uncertainty remains about the true magnitude of the effect of laser on wound contraction in animals; our results should therefore be interpreted with caution.
引用
- Deana NF, Zaror C, Del Sol M, et al. Wound contraction rate in excised and unexcised burn wounds with laser photobiomodulation: Systematic review and meta-analysis of preclinical studies. Burns. 2022. PMID: 35842272. doi:10.1016/j.burns.2022.05.009
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。