动脉脉搏波分析在烧伤复苏中的潜力:一项在体初步研究
研究在40%体表面积烧伤并接受不同复苏方案的猪模型中,比较脉搏波分析(PWA)衍生指标与 Swan-Ganz 参考心输出量(CO)、每搏量(SV)的一致性,并比较 PWA 指标与尿量(UOP)对复苏充分性的判定。结果显示 PWA 衍生指标变化趋势与参考 CO、SV 一致,但在判定复苏充分性时与 UOP 存在明显差异,作者认为 PWA 衍生指标对 UOP 可能有补充价值。
要点
- 猪40%体表面积烧伤模型中,PWA衍生CO、SV指数变化趋势与参考CO、SV一致。
- 校准后CO一致性界限为±24.7 ml/min/kg,SV为±0.30 ml/kg。
- PPV、SPV与参考SV呈反向关系,校准后一致性界限分别为±0.32 ml/kg和±0.31 ml/kg。
核心结论
- 作者认为PWA衍生指标对UOP在评估和指导烧伤复苏方面可能有补充价值。
研究设计与样本
- 猪接受40%体表面积烧伤并采用不同复苏方案,在ICU机械通气下监测24小时。
- 猪置入Swan-Ganz导管作为参考CO测量,研究PWA衍生指标纵向变化并比较UOP与PWA指标判定复苏充分性。
主要发现
- PWA衍生CO、SV指数分别与参考CO、SV成比例,校准后CO一致性界限为±24.7 ml/min/kg,SV一致性界限为±0.30 ml/kg。
- PPV、SPV与参考SV成反比,校准后PPV一致性界限为±0.32 ml/kg,SPV一致性界限为±0.31 ml/kg。
- PWA衍生指标与UOP在判定烧伤复苏充分性方面存在明显差异。
临床怎么用
- 原文未据此给出临床推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
While urinary output (UOP) remains the primary endpoint for titration of intravenous fluid resuscitation, it is an insufficient indicator of fluid responsiveness. Although advanced hemodynamic monitoring (including arterial pulse wave analysis [PWA]) is of recent interest, the validity of PWA-derived indices in burn resuscitation extremes has not been established. The goal of this paper is to test the hypothesis that PWA-derived cardiac output (CO) and stroke volume (SV) indices as well as pulse pressure variation (PPV) and systolic pressure variation (SPV) can play a complementary role to UOP in burn resuscitation. Swine were instrumented with a Swan-Ganz catheter for reference CO and underwent a 40% TBSA burns with varying resuscitation paradigms, and were monitored for 24 hours in an ICU setting under mechanical ventilation. The longitudinal changes in PWA-derived indices were investigated, and resuscitation adequacy was compared as determined by UOP vs PWA indices. The results indicated that PWA-derived indices exhibited trends consistent with reference CO and SV measurements: CO and SV indices were proportional to reference CO and SV, respectively (CO: postcalibration limits of agreement [LoA] = ±24.7 [ml/min/kg], SV: postcalibration LoA = ±0.30 [ml/kg]) while PPV and SPV were inversely proportional to reference SV (PPV: postcalibration LoA = ±0.32 [ml/kg], SPV: postcalibration LoA = ±0.31 [ml/kg]). The results also indicated that PWA-derived indices exhibited notable discrepancies from UOP in determining adequate burn resuscitation. Hence, it was concluded that the PWA-derived indices may have complementary value to UOP in assessing and guiding burn resuscitation.
引用
- ArabiDarrehDor G, Kao YM, Oliver MA, et al. The Potential of Arterial Pulse Wave Analysis in Burn Resuscitation: A Pilot In Vivo Study. J Burn Care Res. 2023. PMID: 35809084. doi:10.1093/jbcr/irac097
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。