文献速递显微修复重建创面修复

扩大下斜方肌肌皮瓣中纳入背阔肌节段有助于复杂缺损重建

Inclusion of a latissimus dorsi segment in an extended lower trapezius musculocutaneous flap facilitates complex defect reconstruction.
PubMed 文献 · J Plast Reconstr Aesthet Surg · 2022-04-30

研究对扩大下斜方肌肌皮瓣(LTMF)进行改良,在皮瓣中纳入不同量的背阔肌(LDM)节段,于2014年至2021年用于19例头、颈、肩、对侧胸壁和背部复杂缺损重建。平均皮瓣大小为30.7 cm×10.9 cm,平均LDM面积为113.9 cm²;2例发生部分皮瓣坏死并用局部皮瓣修复继发缺损,其余17例皮瓣完全成活。作者认为,携带LDM节段的LTMF可考虑用于复杂缺损重建及不适合游离皮瓣重建的患者。

要点

  • 保留后肋间动脉分支间吻合,可在扩大LTMF中纳入不同量的背阔肌节段。
  • LDM用于消灭无效腔及修复涉及脑脊液漏、感染、放射性骨髓炎、颈动脉外露、肺和植入物外露的创面。
  • 19例中2例部分皮瓣坏死、17例皮瓣完全成活,平均皮瓣大小30.7 cm×10.9 cm。

核心结论

  • 携带背阔肌节段的扩大下斜方肌肌皮瓣可考虑用于头、颈、肩、对侧胸壁和背部复杂缺损重建,以及不适合游离皮瓣重建的患者。

研究设计与样本

  • 2014年至2021年,采用改良扩大下斜方肌肌皮瓣(增加背阔肌节段)重建头、颈、肩、对侧胸壁和背部复杂缺损共19例。

主要发现

  • 平均皮瓣大小为30.7 cm×10.9 cm(范围25 cm×8 cm至40 cm×14 cm)。
  • 平均背阔肌面积为113.9 cm²(范围27.7-216.6 cm²)。
  • 2例发生部分皮瓣坏死,继发缺损用局部皮瓣重建;其余17例皮瓣完全成活。

临床怎么用

  • 作者认为,携带背阔肌节段的LTMF可考虑用于头、颈、肩、对侧胸壁和背部复杂缺损重建,以及不适合游离皮瓣重建的患者。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

The pedicled lower trapezius musculocutaneous flap (LTMF) can extend far beyond the lateral border of the trapezius muscle, with a reliable blood supply. However, the distal part of the extended LTMF lacks a muscular component, limiting its usage in complex defect reconstruction, which often requires obliteration of dead space and coverage of vital structures. To overcome this limitation, we modified the LTMF by adding a segment of latissimus dorsi muscle (LDM). Between 2014 and 2021, the modified extended LTMF was used to reconstruct complex defects in the head, neck, shoulder, and contralateral chest wall and back in 19 patients. By preserving the interconnections between the branches of the posterior intercostal arteries, we were able to include various amounts of LDM within the extended LTMF. The LDM component was used to obliterate dead space and repair wounds involving cerebrospinal fluid leakage, infection, radioactive osteomyelitis, exposed carotid artery, lung, and implant materials. The average flap size was 30.7 cm × 10.9 cm (range: 25 × 8 cm-40 × 14 cm). The average size of the LDM was 113.9 cm2 (range: 27.7-216.6 cm2). Partial flap necrosis occurred in two patients and the secondary defects were reconstructed using a local flap. The remaining 17 flaps survived completely. The LTMF carrying a segment of the LDM could be considered for patients undergoing reconstruction of complex defects in the head, neck, shoulder, and contralateral chest wall and back and for patients who are ineligible for free flap reconstruction.

来源:J Plast Reconstr Aesthet Surg,查看原文。版权归原作者所有。

引用

  1. Xie T, Wang M, Zang M, et al. Inclusion of a latissimus dorsi segment in an extended lower trapezius musculocutaneous flap facilitates complex defect reconstruction. J Plast Reconstr Aesthet Surg. 2022. PMID: 35654689. doi:10.1016/j.bjps.2022.04.053

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。