新型创新三维活体模型用于高级显微外科与超显微外科培训:动物模型的替代方案
研究旨在利用鸡胚绒毛尿囊膜模型作为超显微外科与显微外科的创新多功能培训模型,以减少培训用动物数量。该模型提供多种不同尺寸血管用于吻合,血管系统可承受组织机械应力,吻合口通畅性可验证。将绒毛尿囊膜模型整合入外科培训项目可凭借其逼真的解剖生理模型提升培训质量,并符合替代、优化与减少的动物 sparing 原则。
要点
- 鸡胚绒毛尿囊膜模型提供多种尺寸血管,可用于超显微外科与显微外科吻合培训。
- 该模型血管系统可承受组织机械应力,吻合口通畅性可验证手术效果。
- 绒毛尿囊膜模型符合替代、优化与减少原则,可作为动物 sparing 的显微外科培训模型。
核心结论
- 绒毛尿囊膜模型是一种功能良好的超显微外科与显微外科培训模型,可减少培训用动物数量。
- 将绒毛尿囊膜模型整合入外科培训项目可通过提供逼真解剖生理模型及多种血管结构提升培训质量。
- 该模型符合替代、优化与减少原则,有潜力作为创新显微外科培训模型改善手术技能。
研究设计与样本
- 研究利用鸡胚绒毛尿囊膜作为超显微外科与显微外科培训模型。
- 鸡胚绒毛尿囊膜在胚胎发生过程中形成,是受精鸡蛋内高度血管化、无神经支配的膜。
主要发现
- 绒毛尿囊膜模型提供多种不同尺寸血管用于实施吻合,证明其作为超显微外科与显微外科培训模型功能良好。
- 该模型循环系统足以承受施加于组织的机械应力,吻合口通畅性可检测以验证操作。
- 将绒毛尿囊膜模型整合入外科培训项目可通过代表逼真解剖生理模型及多种血管结构提升培训质量。
临床怎么用
- 作者认为将绒毛尿囊膜模型整合入外科培训项目可提升培训质量。
- 作者认为绒毛尿囊膜模型符合替代、优化与减少原则,有潜力作为创新显微外科培训模型改善手术技能。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Microsurgery and supermicrosurgery are surgical subdomains necessary for a large variety of surgical disciplines. So far, there is no training model for lymphatic surgery or perforator flap surgery, and the most commonly used microsurgical training models are living animals. However, the ethical principles of replacement, refinement, and reduction (the three Rs) of living animals for training purposes were implemented, highlighting the necessity of an animal-sparing microsurgical training model. Formed during embryogenesis, the chick chorioallantoic membrane resembles a highly vascularized, noninnervated membrane within fertilized chicken eggs. The aim of this study was to utilize the chorioallantoic membrane model as an innovative and versatile training model for supermicrosurgery and microsurgery that can reduce the number of animals used for these purposes. The variety of different sized vessels for the implementation of an anastomosis proved the chorioallantoic membrane model as a well-functioning supermicrosurgical and microsurgical training model. The circulatory system is resilient enough to withstand the mechanical stress applied to the tissue, and the patency of the implemented anastomosis can be tested for the verification of the procedures. In summary, the integration of the chorioallantoic membrane model into a surgical training program can benefit its quality by representing a realistic anatomical and physiological model with a high variety of vascular structures. Moreover, the chorioallantoic membrane model satisfies the principles of replacement, refinement, and reduction as an animal-sparing model, indicating the potential of this model as an innovative microsurgical training model for the improvement of surgical skills.
引用
- Pion E, Zucal I, Troebs J, et al. New, Innovative, Three-Dimensional In Vivo Model for High-Level Microsurgical and Supermicrosurgical Training: A Replacement for Animal Models. Plast Reconstr Surg. 2022. PMID: 35674658. doi:10.1097/PRS.0000000000009330