文献速递显微修复重建创面修复

头颈部显微外科重建的澳大利亚患者中手术风险预测计算器的验证

Validation of a risk prediction calculator in Australian patients undergoing head and neck microsurgery reconstruction.
PubMed 文献 · J Plast Reconstr Aesthet Surg · 2022-05-01

本研究为回顾性队列研究,纳入200例在澳大利亚三级转诊中心接受显微游离皮瓣重建的连续患者,评估美国外科医师学会国家手术质量改进计划手术风险计算器(SRC)的效度。结果显示,SRC对肺炎和尿路感染有较好区分度,对再入院和脓毒症校准良好,但对任一单一结局的区分度和校准均不佳;预测住院时间与实际住院时间在重建部分相关性差,在切除部分相关性强。结论认为SRC对头颈部显微外科重建患者的术后并发症率和住院时间预测效果差。

要点

  • SRC对肺炎和尿路感染区分度好,对再入院和脓毒症校准好。
  • SRC对任一单一结局的区分度和校准均不佳。
  • SRC预测住院时间与实际住院时间在重建部分相关性差,在切除部分相关性强。

核心结论

  • SRC对接受头颈部显微外科重建患者的术后并发症率和住院时间预测效果差。

研究设计与样本

  • 回顾性队列研究,纳入200例连续患者,截至2020年11月,在澳大利亚三级转诊中心接受显微游离皮瓣重建。

主要发现

  • 对于切除和重建部分,SRC对肺炎和尿路感染区分度好,对再入院和脓毒症校准好,但对任一单一结局的区分度和校准均不佳。
  • SRC预测住院时间与实际住院时间在重建部分相关性差,在切除部分相关性强。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The American College of Surgeons (ACS) National Surgical Quality Improvement Program (NSQIP) surgical risk calculator (SRC) is an open access calculator predicting patients' risk of postoperative complications. This study aims to assess the validity of the SRC in patients undergoing microsurgical free flap reconstruction at an Australian tertiary referral centre. METHODS: This is a retrospective cohort study of 200 consecutive patients treated up to November 2020. SRC-predicted rates of postoperative complications and hospital length of stay (LOS) were compared to those observed for the ablative and reconstructive components of the procedure. The performance of the SRC was assessed using Brier scores, area under the receiver operating characteristic (ROC) curve (AUC), and the Hosmer-Lemeshow test. RESULTS: For both ablative and reconstructive components, the SRC discriminates well for pneumonia and urinary tract infection, and it is calibrated well for readmission and sepsis, but it does not discriminate and calibrate well for any single outcome. SRC-predicted hospital LOS and actual LOS did not correlate well for the reconstructive component, but they correlated strongly for the ablative component. CONCLUSIONS: The SRC is a poor predictor of postoperative complication rates and hospital LOS in patients undergoing head and neck microsurgical reconstruction.

来源:J Plast Reconstr Aesthet Surg,查看原文。版权归原作者所有。

引用

  1. Yung AE, Wong G, Pillinger N, et al. Validation of a risk prediction calculator in Australian patients undergoing head and neck microsurgery reconstruction. J Plast Reconstr Aesthet Surg. 2022. PMID: 35768291. doi:10.1016/j.bjps.2022.04.073

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。