鼻整形术中使用辐照同种异体肋软骨相关并发症:系统综述与Meta分析
该系统综述与Meta分析纳入10项研究共959例患者,评估鼻整形术中使用辐照同种异体肋软骨(IHCC)的并发症发生率;采用随机效应模型,结果显示翘曲2.07%、感染1.77%、吸收1.34%、移位2.13%、翻修2.99%、挤出0.16%、撕脱2.04%,总体长期并发症率低,翻修和移位在一年随访时最常见。
要点
- 鼻整形术中使用IHCC的总体长期并发症率低。
- 一年随访时翻修(2.99%)和移位(2.13%)是最常见并发症。
- 作者认为IHCC可作为鼻整形的可靠材料并获得良好患者满意度。
核心结论
- 鼻整形术中使用IHCC的总体长期并发症率低,翻修和移位在一年随访时最常见,作者认为IHCC可作为鼻整形的可靠材料并获得良好患者满意度。
研究设计与样本
- 系统综述与Meta分析,检索PubMed、Embase和Cochrane Library数据库,纳入至少10例患者且评估至少1项鼻整形术后长期并发症的临床研究,共纳入10项研究、959例患者,采用随机效应模型进行Meta分析。
主要发现
- 翘曲发生率为2.07%(95%CI 0.80%-5.23%)。
- 感染发生率为1.77%(95%CI 1.10%-2.83%)。
- 吸收发生率为1.34%(95%CI 0.34%-5.16%)。
- 移位发生率为2.13%(95%CI 0.86%-5.19%)。
- 翻修发生率为2.99%(95%CI 1.24%-7.03%),挤出发生率为0.16%(95%CI 0.01%-3.25%),撕脱发生率为2.04%(95%CI 1.02%-4.02%)。
临床怎么用
- 作者认为,术者应特别关注翻修和移位的风险。
- 作者认为,IHCC可作为鼻整形的可靠材料并获得良好患者满意度。
局限性
- 所有纳入试验的方法学质量中至高等,但样本量小且部分并发症为主观报告。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The use of irradiated homologous costal cartilage (IHCC) as an alternative source of graft material for rhinoplasty remains controversial because of the risk of complications. Herein, we aimed to perform a comprehensive assessment of complications associated with IHCC use in rhinoplasty through a meta-analysis of published studies. METHODS: We searched the PubMed, Embase, and Cochrane Library databases to identify eligible published studies, and we evaluated the complication rates of IHCC use in rhinoplasty. Published studies meeting the inclusion criteria included clinical studies involving at least 10 patients and assessing at least 1 postoperative long-term complication of rhinoplasty. Two investigators independently extracted data from the included studies using a standardized form. Meta-analysis was performed using a random-effects model. The main outcomes were the rates of various complications, including the need for revision surgery. RESULTS: Ten studies involving a total of 959 patients were analyzed. The complication rates were 2.07% (95% confidence interval [CI], 0.80%-5.23%) for warping, 1.77% (95% CI, 1.10%-2.83%) for infection, 1.34% (95% CI, 0.34%-5.16%) for resorption, 2.13% (95% CI, 0.86%-5.19%) for displacement, 2.99% (95% CI, 1.24%-7.03%) for revision, 0.16% (95% CI, 0.01%-3.25%) for extrusion, and 2.04% (95% CI, 1.02%-4.02%) for avulsion. All the included trials had moderate-to-high methodological quality except for small sample sizes and subjectively reporting of some complications. CONCLUSIONS: The overall long-term complication rates associated with IHCC use in rhinoplasty were low. Revision and displacement were the most common complications at the one-year follow-up; surgeons should pay special attention to the risk of these complications. IHCC can serve as a reliable material for rhinoplasty and achieve good patient satisfaction.
引用
- Luan CW, Chen MY, Yan AZ, et al. Complications associated with irradiated homologous costal cartilage use in rhinoplasty: A systematic review and meta-analysis. J Plast Reconstr Aesthet Surg. 2022. PMID: 35354546. doi:10.1016/j.bjps.2022.02.026
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。