文献速递乳房整形与再造

胸肌前乳房再造中假体移位:Natrelle®黏性假体6.5年经验

Implant Malposition in Prepectoral Breast Reconstruction: Experience with Natrelle® Cohesive Implants over 6.5 Years.
PubMed 文献 · J Plast Reconstr Aesthet Surg · 2022-03-06

回顾性分析2014年1月至2020年5月本院375例(660侧)胸肌前假体乳房再造,光滑圆形假体移位需干预率5.9%,纹理解剖型1.4%;多变量分析显示光滑圆形假体(aHR 7.19,95%CI 2.04-25.4)和假体体积增加(aHR 1.003,95%CI 1.001-1.006)与移位需干预相关。

要点

  • 光滑圆形假体移位需干预率5.9%(26/441),纹理解剖型1.4%(3/219)。
  • 光滑圆形假体(aHR 7.19)与假体体积增加(aHR 1.003)为移位需干预的预测因素。
  • 光滑圆形假体中INSPIRA® Cohesive假体较其他光滑圆形假体更易发生需干预的移位(p<0.0001)。

核心结论

  • 光滑圆形假体和假体体积增加均与胸肌前乳房再造后需干预的假体移位相关。

研究设计与样本

  • 回顾性分析2014年1月至2020年5月在本机构接受Natrelle®假体胸肌前乳房再造的患者,共375例(660侧乳房)。

主要发现

  • 441侧(66.8%)使用光滑圆形假体,219侧(33.2%)使用纹理解剖型假体。
  • 需手法复位或手术干预的移位发生于26侧(5.9%)光滑圆形假体 vs 3侧(1.4%)纹理解剖型假体。
  • 多变量分析显示光滑圆形假体(aHR 7.19,95%CI 2.04-25.4)和假体体积增加(aHR 1.003,95%CI 1.001-1.006)与需干预的移位相关。
  • 光滑圆形假体中,INSPIRA® Cohesive假体较其他光滑圆形假体更易导致需干预的移位(p<0.0001)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Implant malposition has been reported to be a common reason for revision surgery after implant-based breast reconstruction (IBR). With the recent increase in the use of smooth implants due to concerns for breast implant-associated anaplastic large-cell lymphoma with textured implants, we compared and reported the rates of malposition in prepectoral IBR and identified risk factors. A retrospective review of patients who underwent prepectoral IBR with Natrelle® (Allergan, Inc., Irvine, CA) implants at our institution between January 2014 and May 2020 was performed. Clinical characteristics, implant types, and the rate of malposition, defined as implant flipping or rotation, were recorded. Univariate and multivariable time-to-event analyses using the Cox proportional-hazards model were performed to identify predictors of malposition. Three hundred seventy-five patients (660 breasts) were included. Four hundred forty-one (66.8%) breasts had smooth round implants whereas 219 (33.2%) had textured anatomical devices. Malposition requiring either a manual correction or surgical intervention occurred in 26 (5.9%) smooth round implants versus 3 (1.4%) textured anatomical. Multivariable analysis showed that having a smooth round implant (aHR: 7.19, 95% CI: [2.04 - 25.4]) and an increase in implant volume (aHR: 1.003, 95% CI: [1.001 - 1.006]) were associated with having a malposition requiring intervention. Among smooth round implants; INSPIRA® Cohesive implants were more likely to result in a malposition requiring intervention (p<0.0001) compared to other smooth round implants. Overall, malposition requiring intervention occurred in 5.9% of smooth round implants and 1.4% of textured anatomical implants. Statistical analysis demonstrates that smooth round implants and an increase in implant volume both are associated with a malposition requiring intervention.

来源:J Plast Reconstr Aesthet Surg,查看原文。版权归原作者所有。

引用

  1. Kuruoglu D, Harless CA, Tran NV, et al. Implant Malposition in Prepectoral Breast Reconstruction: Experience with Natrelle® Cohesive Implants over 6.5 Years. J Plast Reconstr Aesthet Surg. 2022. PMID: 35370117. doi:10.1016/j.bjps.2022.02.072

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。