数字化导板对正颌手术中颌间固定螺钉植入位置准确性的影响

Effect of a digital guide on the positional accuracy of intermaxillary fixation screw implantation in orthognathic surgery.
PubMed 文献 · J Plast Reconstr Aesthet Surg · 2022-03-05

前瞻性研究纳入2017年8月至2021年5月在青岛大学附属医院行正颌手术的40例患者,随机分为数字化导板组与对照组各20例,术后锥形束CT比较螺钉与牙根的接近程度。导板组无牙根损伤,牙周膜损伤发生率为22.1%,77.9%的螺钉未接触邻近解剖结构;对照组牙根损伤率高达20.8%,牙周膜损伤率31.7%,仅47.5%的螺钉位于牙根之间(P < 0.001)。结论认为使用手术导板可更准确地放置颌间固定螺钉,降低牙根和牙周膜损伤的发生率。

要点

  • 导板组无牙根损伤,对照组牙根损伤率高达20.8%(P < 0.001)。
  • 导板组牙周膜损伤率22.1%,对照组31.7%(P < 0.001)。
  • 导板组77.9%螺钉未接触邻近结构,对照组仅47.5%位于牙根之间。

核心结论

  • 使用手术导板可更准确地放置颌间固定螺钉,降低牙根和牙周膜损伤的发生率。

研究设计与样本

  • 前瞻性研究纳入2017年8月至2021年5月在青岛大学附属医院行正颌手术的40例患者,随机分为数字化导板组和对照组各20例。

主要发现

  • 导板组无牙根损伤病例,牙周膜损伤发生率为22.1%,77.9%的颌间固定螺钉未接触邻近解剖结构。
  • 对照组牙根损伤率高达20.8%,31.7%的颌间固定螺钉损伤牙周膜,仅47.5%的螺钉位于牙根之间(P < 0.001)。

关键数值与推荐

  • 导板组牙周膜损伤发生率22.1%,对照组31.7%(P < 0.001)。
  • 导板组77.9%的颌间固定螺钉未接触邻近解剖结构,对照组47.5%的螺钉位于牙根之间(P < 0.001)。
  • 导板组牙根损伤率为0,对照组牙根损伤率高达20.8%(P < 0.001)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Intermaxillary fixation screw (IMFS) implantation is a common procedure in orthognathic surgery (OGS) performed to the temporary maxillary-mandibular fixation and stable bite relationships. The study aims to assess the accuracy of IMFS implantation with a digital guide to reduce the occurrence of root damage. METHODS: This prospective study involved 40 patients undergoing OGS at the Affiliated Hospital of Qingdao University from August 2017 to May 2021. The patients were randomly divided into two groups according to whether the IMFS implantation was with or without digital guide (20 patients in the experimental group and 20 controls). The digital guides used in the experimental group were designed according to a virtual implantation plan and printed using stereolithography. In the control group, IMFSs were directly implanted by a surgeon based on clinical experience. Postoperatively, cone-beam computed tomography was performed to compare root proximity of IMFSs between the two groups and verify the accuracy of IMFS placement. RESULTS: In the experimental group, there was no case of root damage, the incidence of the periodontal ligament (PDL) injured was 22.1%, and 77.9% IMFSs were placed without contacting adjacent anatomic structures. In the control group, the incidence of root damage had been up to 20.8%, 31.7% IMFSs injured the PDL, and only 47.5% IMFSs were placed between the roots (P < 0.001). CONCLUSION: IMFSs can be placed more accurately with surgical guides, reducing the incidence of root and PDL damages.