文献速递颅颌面外科显微修复重建

实时术中计算机断层扫描可提高虚拟手术规划在双管腓骨瓣下颌骨重建中的准确性

Real-time intraoperative computed tomography can accurize virtual surgical planning on the double-barrel fibular flap for mandibular reconstruction.
PubMed 文献 · J Plast Reconstr Aesthet Surg · 2022-03-14

本文报告7例口腔肿瘤患者接受9个双管腓骨瓣及2个游离皮瓣移植,采用虚拟手术规划、CAD/CAM与术中CT图像融合。6例术中修正腓骨与钛板使图像融合体积从74.71%提高至82.57%,术后5例牙间中线偏差小于2mm,5个标志点平均偏差小于1mm。作者认为术中CT可提升下颌骨空间框架与咬合平面的准确性。

要点

  • 7例患者共11个游离瓣全部移植成功,无需再次探查。
  • 6例术中修正腓骨与钛板,图像融合体积从74.71%提高至82.57%。
  • 5个标志点(双侧髁突、双侧下颌角、颏前点)平均偏差小于1mm。

核心结论

  • CAD/CAM可使虚拟手术实际用于双管腓骨瓣下颌骨缺损重建。
  • 数字手术室中智能技术的共生使术中CT能提升下颌骨空间框架与咬合平面的准确性。

研究设计与样本

  • 本文为系列病例报告,共7例因口腔肿瘤接受游离瓣移植的患者,其中5例骨放射性坏死、2例节段性下颌骨缺损、2例成釉细胞瘤。
  • 患者接受9个双管腓骨瓣和2个游离皮瓣移植。
  • 腓骨瓣采用虚拟手术规划重建,包括CAD/CAM模拟3D模型、受区与腓骨截骨的切割导板,以及数字手术室中用于图像融合的术中CT。

主要发现

  • 下颌骨缺损范围为5-16cm(平均9.56cm),双管腓骨使用2-5根腓骨支柱(平均3.67根)进行图像融合。
  • 1例需用静脉移植重建动脉,全部11个游离瓣移植成功,无需再次探查。
  • 6例术中修正腓骨与钛板,使覆盖图像融合体积从74.71%提高至82.57%。
  • 术后5例患者牙间中线偏差小于2mm,4例无牙颌患者获得良好复位图像。
  • 包括双侧髁突、双侧下颌角和颏前点在内的5个标志点平均偏差小于1mm。

临床怎么用

  • 作者认为CAD/CAM可使虚拟手术实际用于双管腓骨瓣下颌骨缺损重建。
  • 作者认为数字手术室中智能技术的共生使术中CT能提升下颌骨空间框架与咬合平面的准确性。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

UNLABELLED: Real-time intraoperative computed tomography created the accuracy of less than 1 mm deviation in virtual surgical planning double barrel fibular flap for mandibular reconstruction-the symbiosis of intelligent technology in a digital OR. BACKGROUND: With the intelligent technology of virtual surgical planning, CAD/CAM, and intraoperative CT(iCT) in a digital OR, the secondary mandibular defect or primary amelobalstoma mandibulectomy can be restored using double barrel fibula and be achieved precision medicine purpose. MATERIAL AND METHOD: A series of 7 patients underwent free flap for oral cancers who sustained 5 osteoradionecrosis, 2 segmental mandibular defect, and 2 ameloblastoma. They received 9 double barrel fibula flap and 2 free skin flaptransfers. The fibula flap were reconstructed using a virtual surgical planning including CAD/CAM for simulation 3D model, cutting guides for recipient sites and fibulas osteotomy, and iCT for image fusion in a digital OR. RESULT: The mandibular defect was 5-16 cm (average: 9.56 cm), and 2-5 fibular struts for double barrel fibula (average: 3.67 struts) image fusion. One vein graft for artery was required and all 11 flaps were transferred successfully without reexploration. Six patients had intraoperative revision of the fibula and plate to improve the onlay image fusion volume from 74.71 to 82.57%. The postoperative inter-incisor midline deviation was less than 2 mm in 5 patients, and well reduction image in 4 edentulous patients. Five landmarks including bilateral condyles, bilateral gonions, and gnathion demonstrated deviation less than 1 mm in average. CONCLUSION: CAD/CAM can allow a practical virtual surgery to restore mandibular defect reconstruction using a double barrel fibula. The symbiosis of intelligent technology in a digital OR, the iCT can promote the accuracy of mandibular spatialframework and occlusion plain.

来源:J Plast Reconstr Aesthet Surg,查看原文。版权归原作者所有。

引用

  1. Lin CH, Hsu CH, Adarsh K, et al. Real-time intraoperative computed tomography can accurize virtual surgical planning on the double-barrel fibular flap for mandibular reconstruction. J Plast Reconstr Aesthet Surg. 2022. PMID: 35466077. doi:10.1016/j.bjps.2022.02.083

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。