骨骼肌超声在急性烧伤环境中的可靠性与可行性

Reliability and feasibility of skeletal muscle ultrasound in the acute burn setting.
PubMed 文献 · Burns · 2022-03-17

这项多中心研究在20例烧伤成人入院后由两名评估者使用B型超声测量股四头肌肌层厚度(QMLT)和股直肌横截面积(RF-CSA),比较单次与平均值测量、近端与远端位置、最大压迫与无压迫技术。采用平均值测量时QMLT的ICC>0.97、RF-CSA的ICC>0.95,无压迫技术相对最小可检测变化小于最大压迫(6.5% vs 15%)。结论认为超声可提供可行且可靠的股四头肌结构数值。

要点

  • 采用平均值测量时QMLT的ICC>0.97、RF-CSA的ICC>0.95。
  • 无压迫技术相对最小可检测变化为6.5%,最大压迫为15%。
  • 无压迫测量QMLT在近端和远端的可行性分别为94%和96%。

核心结论

  • 超声可提供可行且可靠的股四头肌结构数值,可适应急性烧伤环境常见的临床场景。

研究设计与样本

  • 多中心研究,纳入20例烧伤成人,入院后由两名评估者使用B型超声测量QMLT和RF-CSA。

主要发现

  • 20例烧伤成人年龄50岁(95%CI 42-57)、TBSA 32%(95%CI 23-40)。
  • 采用平均值测量时,QMLT在任一位置和压迫技术下ICC均>0.97,RF-CSA的ICC>0.95。
  • 相对最小可检测变化无压迫技术为6.5%,最大压迫为15%。
  • 无压迫测量QMLT在近端和远端的可行性分别为94%和96%。
  • 9.5%的病例最大压迫不可行,95%的RF-CSA测量成功完成。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Despite the impact of muscle wasting after burn, tools to quantify muscle wasting are lacking. This multi-centre study examined the utility of ultrasound to measure muscle mass in acute burn patients comparing different methodologies. METHODS: B-mode ultrasound was used by two raters to determine feasibility and inter-rater reliability in twenty burned adults following admission. Quadriceps muscle layer thickness (QMLT) and rectus femoris cross-sectional area (RF-CSA) were measured, comparing the use of i) a single versus average measurements, ii) a proximal versus distal location for QMLT, and iii) a maximum- versus no-compression technique for QMLT. RESULTS: Analysis of twenty burned adults (50 years [95%CI 42-57], 32%TBSA [95%CI 23-40]) yielded ICCs of> 0.97 for QMLT (for either location and compression technique) and> 0.95 for RF-CSA, using average measurements. Relative minimal detectable changes were smaller using no-compression than maximum-compression (6.5% vs. 15%). Using no-compression to measure QMLT was deemed feasible for both proximal and distal locations (94% and 96% of attempted measurements). In 9.5% of cases maximum-compression was not feasible. 95% of RF-CSA measurements were successfully completed. CONCLUSION: Ultrasound provides feasible and reliable values of quadriceps muscle architecture that can be adapted to clinical scenarios commonly encountered in acute burn settings.

来源:Burns,查看原文。版权归原作者所有。