文献速递烧伤创面修复

比较肿胀浸润技术在烧伤手术中的效率

Comparing the Efficiency of Tumescent Infiltration Techniques in Burn Surgery.
PubMed 文献 · J Burn Care Res · 2022-01-01

单中心连续纳入需行削痂植皮的成人烧伤患者并随机分组,比较手动注射器与泵装置行稀释肾上腺素(1:500,000)肿胀浸润的效率;泵法达到肿胀终点所需时间更短、动作更少、浸润液量更少。

要点

  • 泵法达到肿胀终点的时间为2.0 vs 手动1.1 cm2/s(P < .001)。
  • 泵法每动作覆盖面积37.8 vs 手动1.1 cm2/move(P < .001)。
  • 泵法所需肿胀液量1.7 vs 手动2.4 mL/cm2(P = .01)。

核心结论

  • 与手动技术相比,浸润泵在时间和动作经济性方面均显著更高效。
  • 这些减少可能有助于提高手术室效率并减轻操作者疲劳。

研究设计与样本

  • 单中心连续纳入需行削痂植皮的成人烧伤患者,随机分为手动组或泵组。
  • 排除削痂面积小于2% TBSA者及特定解剖区域(如头颈部)。
  • 由单一术者以肾上腺素溶液(1:500,000)浸润至肿胀终点,并录像编码记录持续时间、动作次数和注射肿胀液量。
  • 共纳入14例患者,16例次随机分配至手动组(N = 8)或泵浸润组(N = 8)。

主要发现

  • 泵法达到目标肿胀终点所需时间更短(2.0 vs 1.1 cm2/s,P < .001)。
  • 泵法达到目标肿胀终点所需动作次数更少(37.8 vs 1.1 cm2/move,P < .001)。
  • 泵法达到肿胀终点所需肿胀液量更少(1.7 vs 2.4 mL/cm2,P = .01)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Tangential excision and grafting of burn wounds result in significant intraoperative blood loss, and infiltration of a dilute epinephrine solution (tumescence) is routinely performed to reduce such bleeding. Tumescent infiltration has been described using both a manual technique (syringe) and a pump device. The purpose of this study is to compare the efficiency of these two methods in terms of time and economy of motion. Consecutive adult burn patients at a single center requiring excision and grafting were enrolled in the study and randomized into either the manual or pump technique. Excisions involving less than 2% TBSA were excluded, along with specific anatomic regions (eg, head and neck). Infiltration with epinephrine solution (1:500,000) was performed to the endpoint of tumescence by a single surgeon and filmed/coded for duration, number of maneuvers, and volume of tumescence injected. Fourteen patients were enrolled, and 16 cases were randomized to either manual (N = 8) or pump infiltration (N = 8). The pump method required less time (2.0 vs 1.1 cm2/s, P < .001) and fewer maneuvers (37.8 vs 1.1 cm2/move, P < .001) to reach the desired endpoint of tumescence. Use of the infiltration pump also resulted in a reduced volume of tumescent fluid required to reach this point of tumescence (1.7 vs 2.4 mL/cm2, P = .01). Compared to the manual technique, an infiltration pump was significantly more efficient in terms of both time and economy of motion. These reductions are potentially useful for improving operating room efficiency as well as minimizing operator fatigue.