三维扫描在假体乳房再造中真的有用吗:一项前瞻性研究

Is 3-Dimensional Scanning Really Helpful in Implant-Based Breast Reconstruction?: A Prospective Study.
PubMed 文献 · Ann Plast Surg · 2022-01-01

该前瞻性研究纳入12例早期乳腺癌行保留乳头乳房切除并即刻假体再造患者,术前用Artec Eva三维扫描仪测量乳房体积,术中用水置换法测量切除标本体积。术前三维扫描乳房体积与术中标本体积呈统计学显著相关(r=0.6578),但术前乳房体积与最终假体体积、标本体积与最终假体体积、预估假体体积与最终假体体积均无相关性。作者认为该扫描仪可较准确测量乳房体积,但如何用于乳房切除与假体选择仍需更多研究,可能更适用于隆乳术前规划。

要点

  • 术前Artec Eva三维扫描乳房体积与术中乳房切除标本体积呈统计学显著相关(r=0.6578)。
  • 术前乳房体积与最终假体体积、标本体积与最终假体体积、预估与最终假体体积均无相关性。
  • 作者认为三维扫描可能更适用于隆乳术前规划,用于假体选择仍需更多研究。

核心结论

  • Artec Eva三维扫描仪可提供相对准确的乳房体积测量,但如何将这些数据应用于乳房切除操作和假体选择仍需多项研究确定。
  • 作者认为该技术可能更适用于隆乳手术的术前规划。
  • 作者提出未来术者还应考虑自然乳房大小、肿瘤大小、癌症分期以及患者和医生偏好等变异均会影响乳房再造结果。

研究设计与样本

  • 本研究为前瞻性研究,纳入12例早期乳腺癌行保留乳头乳房切除并即刻假体再造的患者。
  • 术前使用Artec Eva三维扫描仪获取乳房体积测量,术中用水置换法测量乳房切除标本体积。
  • 采用Pearson相关系数分析术前乳房体积、乳房切除标本体积与预估及最终假体体积之间的相关性,必要时应用85%的校正预测因子。
  • 术后3个月评估患者和医生满意度。

主要发现

  • 术前Artec Eva三维扫描测量的乳房体积与术中乳房切除标本体积之间呈统计学显著相关(r=0.6578)。
  • 术前乳房体积与最终假体体积之间无相关性。
  • 乳房切除标本体积与最终假体体积之间无相关性。
  • 预估假体体积与最终假体体积之间无相关性。

临床怎么用

  • 作者认为Artec Eva三维扫描仪可提供相对准确的乳房体积测量,但如何将这些数据应用于乳房切除操作和假体选择仍需多项研究确定。
  • 作者认为该技术可能更适用于隆乳手术的术前规划。
  • 作者提出未来术者还应考虑自然乳房大小、肿瘤大小、癌症分期以及患者和医生偏好等变异均会影响乳房再造结果。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Breast reconstruction is an integral part of breast cancer treatment, and implant-based breast reconstruction is the most commonly used method worldwide. However, there is still no technique that allows surgeons to predict the volume of the required implant. Although computed tomography and magnetic resonance imaging provide adequate representations of the breast, these procedures are time-consuming, expensive, and expose patients to radiation. Therefore, there is a need for safer, noninvasive alternatives for preoperative breast volume measurements. PATIENTS AND METHODS: This study is a prospective review of 12 patients with early-stage breast cancer who underwent nipple-sparing mastectomy and immediate breast reconstruction with implants. Preoperatively, the Artec Eva 3D scanner was used to acquire volumetric measurements of the breasts. Intraoperatively, the volume of the mastectomy specimen was measured using the water displacement method. Correlations among the preoperative breast, mastectomy specimen, and estimated and final implant volumes were analyzed through Pearson correlation coefficient. A correction prediction factor of 85% was applied where necessary. Patient and physician satisfaction were evaluated 3 months postoperatively. RESULTS: Our study found a statistically significant correlation between the preoperative breast volumes measured by the Artec Eva 3D scanner and intraoperative mastectomy specimen volumes (r = 0.6578). There was no correlation between the preoperative breast volumes and final implant volumes, mastectomy specimen volumes and final implant volumes, and estimated implant volumes and final implant volumes. CONCLUSIONS: Although the Artec Eva 3D scanner can offer relatively accurate measurement of breast volumes, multiple studies still need to be done to determine how these data can be applied to the mastectomy procedure and breast implant selection. It may be more applicable for preoperative planning in breast augmentation surgery. Future surgeons should also take into account that variabilities in natural breast size, tumor size, cancer stage, and in patient and physician preferences all influence the outcome of breast reconstruction surgery.

来源:Ann Plast Surg,查看原文。版权归原作者所有。

引用

  1. Huang DW, Chou YY, Liu HH, et al. Is 3-Dimensional Scanning Really Helpful in Implant-Based Breast Reconstruction?: A Prospective Study. Ann Plast Surg. 2022. PMID: 35225853. doi:10.1097/SAP.0000000000003088

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。