股前外侧皮瓣治疗低压电致四度电烧伤伴肘部即刻桡神经麻痹一例报告
本文报告一例42岁男性右肘480伏特电击伤,致24×10 cm四度烧伤创面并即刻桡神经麻痹。清创确认并保留桡神经连续性后,以游离股前外侧皮瓣覆盖创面,创面愈合顺利。随访Tinel征持续前移,电诊断检查示神经再支配逐步恢复,桡神经功能9个月内完全恢复。作者认为该神经损伤呈「休克-煮熟」样改变,并作为位置良好的神经移植物促进再生。
要点
- 低压电损伤可致四度烧伤创面并即刻单神经麻痹,本例为桡神经。
- 清创时确认并保留桡神经连续性,创面以游离股前外侧皮瓣覆盖后愈合顺利。
- 随访Tinel征持续前移、电诊断示神经再支配逐步恢复,桡神经功能9个月内完全恢复。
核心结论
- 作者认为,本例对创面积极早期清创并及时皮瓣覆盖、对桡神经损伤采取保守治疗,其成功结果可为此类损伤的处理提供更多启示。
研究设计与样本
- 个案报告:一例42岁男性右肘480伏特电击伤致24×10 cm四度烧伤创面并即刻桡神经麻痹。
主要发现
- 清创确认并保留桡神经连续性,创面以游离股前外侧皮瓣覆盖后愈合顺利。
- 随访Tinel征持续前移,电诊断检查示神经再支配逐步恢复。
- 桡神经功能9个月内完全恢复。
- 作者认为该神经损伤呈「休克-煮熟」样改变,并作为位置良好的神经移植物促进后续再生。
临床怎么用
- 作者对本例创面采取积极早期清创并及时皮瓣覆盖,对桡神经损伤采取保守治疗。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
While high-voltage electrical injuries usually cause severe burn wounds and axonal polyneuropathy, low-voltage electrical injuries cause limited cutaneous wounds and demyelinating mononeuropathy, of which the median and ulnar nerves are the most commonly involved. We present the case of a 42-year-old man who suffered a 480-voltage electrical injury at his right elbow, resulting in a 24 × 10 cm fourth-degree burn wound and immediate radial nerve palsy. The burn wound was debrided with confirmation and preservation of radial nerve continuity. The wound was covered with a free anterolateral thigh flap and it healed uneventfully. The Tinel's sign continued to advance at follow-up, and electrodiagnostic studies showed progressive reinnervation. His radial nerve function recovered completely in 9 months. This is a rare case of low-voltage electrical injury with a fourth-degree burn wound and immediate radial nerve palsy. We treated the wound aggressively with early debridement and prompt flap coverage, but conservatively treated the radial nerve injury. The nerve recovery course indicates that it had a "shocked-cooked" injury and served itself as a well-placed nerve graft for the subsequent regeneration. We believe that our successful outcome in this case can provide more insights into the management of such injuries.
引用
- Lai YS, Lee YC. Anterolateral Thigh Flap for Low-Voltage Fourth-Degree Electrical Burn Injury With Immediate Radial Nerve Palsy at the Elbow: A Case Report. J Burn Care Res. 2022. PMID: 35352816. doi:10.1093/jbcr/irac040
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。