文献速递瘢痕与激光烧伤

点阵二氧化碳激光固定与动态模式治疗大面积烧伤的实验模型比较

Comparison of stationary and dynamic fractional CO2 laser modalities of large burns treatment: Experimental laboratory model.
PubMed 文献 · Burns · 2021-12-02

在A4纸堆模拟大面积烧伤瘢痕模型中,比较点阵剥脱性二氧化碳激光固定(盖章式,7×7像素)与动态(滚轮式,7×1像素)两种手具的覆盖率、穿透深度和操作时间,激光设为高功率30 W、能量100 mJ/像素,垂直及倾斜操作。动态手具在垂直和倾斜条件下操作时间更快、穿透更深。

要点

  • 模拟模型中动态滚轮手具较固定盖章手具操作时间更快、穿透更深。
  • 两种手具激光设置均为高功率30 W、能量100 mJ/像素。
  • 结论基于A4纸堆模拟模型,非临床瘢痕组织。

核心结论

  • 在模拟大面积烧伤瘢痕治疗中,点阵剥脱性动态手具较固定手具展示出更优的操作效率,缩短治疗时间并改善穿透深度。

研究设计与样本

  • 实验室内模拟模型研究,使用30 W点阵剥脱性二氧化碳激光在A4纸堆上比较两种手具:固定盖章式7×7(49像素/方形)与动态滚轮式7×1(7像素/单行)。
  • 两种手具激光设置固定为高功率30 W、能量100 mJ/像素,均垂直作用于表面,动态手具另重复倾斜操作条件。

主要发现

  • 动态手具在垂直和倾斜两种条件下操作时间均快于固定手具,穿透深度均深于固定手具。
  • 穿透深度通过纸页上可见孔洞的页数评估,覆盖时间在每种手具/条件下测量。

临床怎么用

  • 作者认为该研究对激光操作者在大面积瘢痕中提高时间效率并改善临床终点具有实践意义。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To experimentally compare two fractional ablative CO2 laser handpieces intended for the treatment of large area burn scars. Each handpiece coverage rate, depth of penetration and application time were measured and compared in a simulation model of large area burns scars using a dynamic/roller handpiece (small footprint) and a stationary/stamping handpiece (large footprint). METHODS: A 30 W fractional ablative CO2 laser was applied using 2 different handpieces and footprints on a A4 size paper stack. The handpieces were a stationary (stamping) handpiece with 7 × 7 (49 pixels/square shape) and dynamic (roller) handpiece with 7 × 1 (7 pixels/single row shape). For both handpieces the laser settings were fixed at "High" power (30 W), providing an energy level of 100 mJ/pixel. Both handpieces were applied perpendicular to the surface, with the process repeated for the dynamic handpiece with an angled operation. The depth of laser penetration was assessed by the number of pages of paper having visible holes and burn area coverage time measured under each handpiece/condition. RESULTS: The application time was faster and the penetration deeper for the dynamic handpiece compared to the stationary handpiece in both the perpendicular and angled conditions. This study has practical implications for lasers operators to improve time efficacy in large area scars with improved clinical endpoints. CONCLUSION: The fractional ablative dynamic handpiece demonstrated superior application efficiency compared to the stationary handpiece in the simulated treatment of large surface area burn scars, reducing treatment time with improved depth of penetration.

来源:Burns,查看原文。版权归原作者所有。

引用

  1. Haik J, Segalovich M, Visentin D, et al. Comparison of stationary and dynamic fractional CO2 laser modalities of large burns treatment: Experimental laboratory model. Burns. 2021. PMID: 35248429. doi:10.1016/j.burns.2021.11.022

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。