个性化弯制钛网眶保留眶重建的准确性:一项比较研究
本研究评估个性化弯制钛网在导航辅助与非导航辅助下对眶保留上颌骨切除术后眶缺损的重建效果,共纳入41例患者,以健侧眶为对照进行眶投影与体积测量。导航辅助组健侧与重建侧眶投影平均差0.8±0.5 mm、眶体积平均差0.9±1.2 cm³;非导航辅助组分别为0.7±0.5 mm和1.3±1.3 cm³,两组间差异均无统计学意义。作者认为使用个性化弯制钛网时,无论是否使用术中导航,均可获得同样满意的眶重建效果。
要点
- 41例眶保留上颌骨切除患者使用个性化弯制钛网行眶底重建,部分联合术中导航。
- 导航辅助组健侧与重建侧眶投影差0.8±0.5 mm,眶体积差0.9±1.2 cm³。
- 非导航辅助组健侧与重建侧眶投影差0.7±0.5 mm,眶体积差1.3±1.3 cm³,两组间差异无统计学意义。
核心结论
- 使用个性化弯制钛网行眶保留上颌骨切除术后眶重建,无论是否联合术中导航,均可获得同样满意的眶重建效果。
研究设计与样本
- 比较性研究,纳入41例接受眶保留上颌骨切除并使用个性化弯制钛网行眶底重建的患者,按是否使用术中导航分组,以健侧眶为对照,进行术前与术后眶投影和体积测量。
主要发现
- 导航辅助组健侧与重建侧眶投影平均差0.8±0.5 mm,眶体积平均差0.9±1.2 cm³。
- 非导航辅助组健侧与重建侧眶投影平均差0.7±0.5 mm,眶体积平均差1.3±1.3 cm³。
- 两组健侧与患侧眶投影平均差比较P=0.744,眶体积平均差比较P=0.677,均无统计学意义。
- 两组术前与术后眶投影平均差比较P=0.659,眶体积平均差比较P=0.582,均无显著差异。
临床怎么用
- 作者认为,使用个性化弯制钛网时,联合或不联合术中导航均可获得同样满意的眶保留上颌骨切除术后眶重建效果。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Accurate reconstruction of orbital and midfacial defects following extensive globe-sparing maxillectomy is challenging, due to the complex anatomy of facial skeleton. The aim of this study is to evaluate the outcomes of individually bent titanium mesh in navigation-assisted reconstruction of post-ablative orbits in comparison with that without intraoperative navigation. Forty-one patients undergone globe-sparing maxillectomy and orbital floor reconstruction using individually bent titanium mesh with or without intraoperative navigation were assessed. Pre- and postoperative orbital projection and volume measurements were performed on both orbits. The unaffected orbit was used as a control for comparison. True-to-original orbital reconstruction was achieved in this study. The average difference of globe projection and orbital volume between unaffected and reconstructed orbits was 0.8 ± 0.5 mm and 0.9 ± 1.2cm3, respectively, in navigation-assisted group. In non-navigation-assisted group, the average difference of globe projection and orbital volume of unaffected and reconstructed orbit was 0.7 ± 0.5 mm and 1.3 ± 1.3cm3, respectively. There was no statistical significance in mean differences between unaffected and affected globe projection (P = 0.744) and orbital volume (P = 0.677) in both groups. There was also no significant difference observed when comparing the mean differences between pre- and postoperative globe projection (P = 0.659) and orbital volume (P = 0.582) in both groups. While intraoperative navigation system was shown to be effective in orbital reconstruction in the past decade, equal satisfactory post-ablative orbital reconstruction can be achieved with individually bent titanium mesh with or without intraoperative navigation.
引用
- Soh HY, Sun Q, Hu LH, et al. Accuracy of globe-sparing orbital reconstruction using individually bent titanium mesh: A comparative study. J Plast Reconstr Aesthet Surg. 2022. PMID: 35168922. doi:10.1016/j.bjps.2022.01.032