文献速递乳房整形与再造显微修复重建

吲哚菁绿近红外荧光成像在游离皮瓣乳房重建中的定量研究

Quantification of near-infrared fluorescence imaging with indocyanine green in free flap breast reconstruction.
PubMed 文献 · J Plast Reconstr Aesthet Surg · 2022-01-14

本研究对接受游离皮瓣乳房重建的患者行吲哚菁绿(ICG)近红外(NIR)荧光成像,动脉和静脉吻合完成后静脉注射7.5 mg ICG,选取穿支、正常灌注、可疑灌注和低灌注四类感兴趣区(ROI)分析时间-强度曲线并提取Tmax和Tmax斜率。共13例患者17个游离皮瓣手术成功完成成像,穿支ROI曲线与正常灌注ROI相当且显示快速流入,可疑灌注和低灌注ROI未见流出。作者认为未来研究应将定量参数与临床灌注评估及结局进行关联。

要点

  • 13例患者17个游离皮瓣术中静脉注射7.5 mg ICG行NIR荧光成像。
  • 穿支ROI时间-强度曲线与正常灌注ROI相当,显示快速流入。
  • 可疑灌注和低灌注ROI未观察到流出。

核心结论

  • 本研究提供了ICG NIR荧光成像在游离皮瓣乳房重建中所观察到的灌注模式的见解。
  • 作者认为未来研究应将定量参数与临床灌注评估及结局进行关联。

研究设计与样本

  • 对接受乳房切除术后游离皮瓣乳房重建的患者行ICG NIR荧光成像。
  • 动脉和静脉吻合完成后静脉注射7.5 mg ICG,使用Quest Spectrum Platform®记录荧光强度随时间变化。
  • 根据位置和NIR荧光信号解读选取4类ROI:穿支、正常灌注、可疑灌注和低灌注。
  • 分析时间-强度曲线并提取Tmax和Tmax斜率两个参数。
  • 共13例患者17个游离皮瓣手术成功完成ICG NIR荧光成像。

主要发现

  • ROI选择包括16个穿支、17个正常灌注、8个可疑灌注和5个低灌注ROI。
  • 穿支ROI的时间-强度曲线与正常灌注ROI相当,并显示快速流入。
  • 可疑灌注和低灌注ROI未观察到流出。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: One of the complications of free flap breast reconstruction is the occurrence of skin and fat necrosis. Intra-operative use of near-infrared (NIR) fluorescence imaging with Indocyanine Green (ICG) has the potential to predict these complications. In this study, the quantification of the fluorescence intensity measured in free flap breast reconstruction was performed to gain insight into the perfusion patterns observed with ICG NIR fluorescence imaging. METHODS: ICG NIR fluorescence imaging was performed in patients undergoing free flap breast reconstruction following mastectomy. After completion of the arterial and venous anastomosis, 7.5 mg ICG was administered intravenously. The fluorescence intensity over time was recorded using the Quest Spectrum Platform®. Four regions of interest (ROI) were selected based on location and interpretation of the NIR fluorescence signal: (1) The perforator, (2) normal perfusion, (3) questionable perfusion, and (4) low perfusion. Time-intensity curves were analyzed, and two parameters were extracted: Tmax and Tmax slopes. RESULTS: Successful ICG NIR fluorescence imaging was performed in 13 patients undergoing 17 free flap procedures. Region selection included 16 perforators, 17 normal perfusions, 8 questionable perfusions, and 5 low perfusion ROIs. Time-intensity curves of the perforator ROIs were comparable to the ROIs of normal perfusion and demonstrated a fast inflow. No outflow was observed for the ROIs with questionable and low perfusion. CONCLUSION: This study provides insight into the perfusion patterns observed with ICG NIR fluorescence imaging in free flap breast reconstruction. Future studies should correlate quantitative parameters with clinical perfusion assessment and outcome.

来源:J Plast Reconstr Aesthet Surg,查看原文。版权归原作者所有。

引用

  1. Van Den Hoven P, Verduijn PS, Van Capelle L, et al. Quantification of near-infrared fluorescence imaging with indocyanine green in free flap breast reconstruction. J Plast Reconstr Aesthet Surg. 2022. PMID: 35131194. doi:10.1016/j.bjps.2021.12.004

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。