镜像技术在眶重建计算机辅助设计中可靠吗?眶不对称性的三维分析

Is the Mirroring Technology Reliable in the Use of Computer-Aided Design for Orbital Reconstruction? Three-Dimensional Analysis of Asymmetry in the Orbits.
PubMed 文献 · Plast Reconstr Surg · 2022-01-01

本研究将104例患者的面部CT数据导入iPlan软件,设定四个参考点并计算其到前鼻棘的三维距离及眶腔体积,由三名整形外科医生独立完成。结果显示双侧参考点间三维距离无统计学显著差异,眶腔体积轻度不对称但可接受,结论认为眶三维位置与解剖对称,镜像技术可作为计算机辅助设计可靠的第一步。

要点

  • 双侧四个参考点至前鼻棘的三维距离无统计学显著差异。
  • 双侧视神经管点至其他参考点的三维距离无统计学显著差异。
  • 眶腔体积呈轻度不对称,但差异在计算机辅助设计应用中可接受。

核心结论

  • 眶的三维位置及三维解剖是对称的,镜像技术可作为计算机辅助设计、计算机辅助手术和导航辅助手术可靠的第一步。

研究设计与样本

  • 将104例患者的面部计算机断层扫描数据导入iPlan软件,设定颧额缝、额上颌缝、眶下孔和视神经管四个参考点并计算其至前鼻棘在镜像平面上的三维距离,同时计算眶腔体积及视神经管点至其他参考点的三维距离,由三名整形外科医生独立完成。

主要发现

  • 双侧前鼻棘与四个参考点之间的三维距离无统计学显著差异。
  • 双侧视神经管代表点与其他参考点之间的三维距离无统计学显著差异。
  • 眶腔体积呈轻度不对称,但该差异在计算机辅助设计应用中可接受。
  • 所有参考点的95%CI最大值均小于1.4 mm。

关键数值与推荐

  • 所有参考点的95%CI最大值均小于1.4 mm。

临床怎么用

  • 作者认为镜像技术可作为计算机辅助设计、计算机辅助手术和导航辅助手术可靠的第一步。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Reconstruction of the orbital area remains a challenge in many cases. The recently introduced mirroring technology provides surgeons with patient-specific information for accurate orbital reconstruction; its premise is that the three-dimensional anatomy of craniofacial bone is symmetric. The purpose of this study was to verify this premise of the mirroring technology by assessing three-dimensional asymmetry. METHODS: Facial computed tomographic data of 104 patients were imported into iPlan software. Four reference points (i.e., zygomaticofrontal suture, frontomaxillary suture, infraorbital foramen, and optic canal) were set, and the three-dimensional distances from these points to the anterior nasal spine on the mirroring plane were calculated. In addition, the orbital cavity volume and the three-dimensional distances from point optic canal to the other reference points were calculated for the assessment of the orbit anatomy. Three plastic surgeons performed these processes independently. RESULTS: No statistically significant difference was found in the three-dimensional distances between anterior nasal spine and the four reference points bilaterally. Also, no statistically significant difference in the three-dimensional distances between the point representing the optic canal and other reference points was detected bilaterally. Orbital cavity volume showed a mild asymmetry, but the discrepancy was acceptable for computer-aided design applications. For all reference points, the maximum value of the 95 percent CI was less than 1.4 mm. CONCLUSIONS: The three-dimensional location of the orbits and the three-dimensional anatomy of the orbit were symmetric. Thus, the mirroring technology could be a reliable first step in computer-aided design, computer-assisted surgery, and navigation-assisted surgery. CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, V.

来源:Plast Reconstr Surg,查看原文。版权归原作者所有。