文献速递乳房整形与再造显微修复重建

近红外荧光评估腹壁下深动脉穿支皮瓣灌注:一项先导研究及标准化工作流程描述

Assessment of deep inferior epigastric perforator flap perfusion with near-infrared fluorescence: A pilot study and description of a standardized working protocol.
PubMed 文献 · J Plast Reconstr Aesthet Surg · 2021-11-16

该前瞻性先导研究纳入24例单侧腹壁下深动脉穿支皮瓣自体重建患者,术中辅以吲哚菁绿近红外荧光成像评估皮瓣灌注,并与24例未使用该技术的回顾性队列比较。荧光组脂肪坏死发生率为4.2%,回顾性组为33%(P=0.023),作者认为荧光成像可显著降低脂肪坏死并提供标准化工作流程。

要点

  • 近红外荧光成像组脂肪坏死发生率为4.2%,回顾性对照组为33%(P=0.023)。
  • 两组患者及手术特征无显著差异,手术时长亦无差异。
  • 显微外科医生对近红外荧光成像持肯定态度,认为其提供额外灌注信息或确认临床评估。

核心结论

  • 本先导研究显示,在腹壁下深动脉穿支皮瓣自体重建术中采用近红外荧光成像评估皮瓣灌注,脂肪坏死发生率显著降低。
  • 本研究提供了近红外荧光成像的标准化工作流程,未来需大型多中心研究聚焦于该技术的量化。

研究设计与样本

  • 前瞻性先导研究,纳入24例接受单侧腹壁下深动脉穿支皮瓣自体重建的患者,术中辅以吲哚菁绿近红外荧光成像评估皮瓣灌注。
  • 将该前瞻性队列与24例未使用近红外荧光成像的回顾性腹壁下深动脉穿支皮瓣手术队列进行比较。
  • 记录并比较患者特征、手术特征及术后并发症。

主要发现

  • 前瞻性荧光组与回顾性对照组的患者及手术特征无显著差异,包括手术时长无差异。
  • 前瞻性荧光组脂肪坏死发生率为4.2%,回顾性对照组为33%(P=0.023)。
  • 显微外科医生对使用近红外荧光成像持肯定态度,因其提供额外灌注信息或确认临床评估。

临床怎么用

  • 作者认为,在腹壁下深动脉穿支皮瓣自体重建术中可使用近红外荧光成像评估皮瓣灌注以降低脂肪坏死。
  • 作者提供了近红外荧光成像的标准化工作流程。

局限性

  • 本研究的性质为先导研究。
  • 未来需大型多中心研究聚焦于近红外荧光成像的量化。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Fat necrosis (FN) is a common complication after autologous breast reconstruction (ABR) using a free flap, which can influence reconstruction outcome and patient satisfaction. Intraoperative near-infrared fluorescence imaging using indocyanine green (ICG) permits the visualization of flap perfusion. The aim of this study was to assess the effect of near-infrared fluorescence on FN incidence in patients undergoing an ABR with a deep inferior epigastric perforator flap (DIEP) and to propose a standard working protocol for this technique. In this prospective study, patients undergoing one-sided ABR with a DIEP were included. The standard DIEP procedure was complemented with near-infrared fluorescence imaging using the fluorescent tracer ICG to evaluate flap perfusion. This cohort was compared to a retrospective cohort of DIEP procedures without near-infrared fluorescence imaging. Patients and surgery characteristics, as well as postoperative complications, were registered and compared. In both cohorts, 24 patients were included. No significant differences were present between patients and surgery characteristics, including no difference in duration of surgery. In the prospective and retrospective group, the incidence of FN was 4.2% and 33%, respectively (p-value = 0.023). Moreover, microsurgeons were positive about using near-infrared fluorescence as it either provided additional information about perfusion or confirmed the clinical assessment. Our pilot study showed a significant decrease of FN in patients undergoing an ABR with a DIEP when near-infrared fluorescence imaging was used to assess flap perfusion. This study provides a standardized working protocol for near-infrared fluorescence imaging. In the future, large multicenter studies should focus on the quantification of near-infrared fluorescence imaging.

来源:J Plast Reconstr Aesthet Surg,查看原文。版权归原作者所有。

引用

  1. Michi M, Verduijn PS, Corion LUM, et al. Assessment of deep inferior epigastric perforator flap perfusion with near-infrared fluorescence: A pilot study and description of a standardized working protocol. J Plast Reconstr Aesthet Surg. 2021. PMID: 34924327. doi:10.1016/j.bjps.2021.11.043

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。