文献速递乳房整形与再造创面修复

脂肪移植对挛缩乳房假体包膜的作用:一项回顾性比较组织学与免疫组化研究

The role of fat grafting on contracted breast implant capsules: A retrospective comparative histological and immunohistochemical study.
PubMed 文献 · J Plast Reconstr Aesthet Surg · 2021-10-19

本研究纳入80例乳房切除术后放疗(PMRT)后出现IV级包膜挛缩、需翻修手术的即刻胸肌下假体乳房再造患者,比较多次自体脂肪移植(lipobed组40例)与未行脂肪移植(NRS组40例)后取出包膜的組織学与免疫组化特征,发现两组在包膜厚度、胶原纤维排列及α-SMA、ER-β、ER-α表达上存在差异。

要点

  • lipobed组包膜平均厚度低于NRS组(602.17 vs 670.43 µm,P=0.013)。
  • lipobed组胶原纤维排列角度偏差中位值高于NRS组(30.34 vs 18.38,P=0.001)。
  • lipobed组α-SMA阳性率低于NRS组(12.5% vs 52.5%,P=0.00),ER-β阳性率高于NRS组(80% vs 20%,P=0.00),ER-α阳性率低于NRS组(53.3% vs 16.7%,P=0.00)。

核心结论

  • 脂肪移植后放疗损伤包膜的組織学与免疫组化特征与未移植者不同,作者认为这些差异可能源于移植脂肪改变的细胞外微环境。

研究设计与样本

  • 回顾性比较研究,纳入80例即刻胸肌下假体乳房再造后因PMRT后IV级包膜挛缩需翻修手术的患者,lipobed组40例(平均年龄48岁)行多次脂肪移植,NRS组40例(平均年龄49岁)未行多次脂肪移植,对取出的包膜行组织学与免疫组化评估。

主要发现

  • lipobed组包膜平均厚度低于NRS组(602.17 vs 670.43 µm,P=0.013)。
  • lipobed组胶原纤维排列角度偏差中位值高于NRS组(30.34 vs 18.38,P=0.001)。
  • lipobed组α-SMA免疫组化阳性率低于NRS组(12.5% vs 52.5%,P=0.00)。
  • lipobed组ER-β免疫组化阳性率高于NRS组(80% vs 20%,P=0.00)。
  • lipobed组ER-α免疫组化阳性率低于NRS组(53.3% vs 16.7%,P=0.00)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Capsular contracture, a common complication of breast implant reconstruction following postmastectomy radiotherapy (PMRT), represents a challenge for plastic surgeons. Regenerative surgery with multiple autologous fat grafts (lipobed) before replacing the implant has been proven to be a satisfactory approach in the radio-damaged breast. Currently, in literature, there are no data available on the histological features of irradiated capsules after regenerative surgery. We enrolled 80 patients after immediate subpectoral alloplastic breast reconstruction, with indication for revision surgery due to grade IV capsular contracture developed after PMRT. Forty patients were undergoing multiple fat grafting (lipobed group, mean age 48) and 40 patients were not undergoing multiple fat grafting (non-regenerative surgery (NRS) group, mean age 49). The removed capsules were addressed to histological and immunohistochemical assessment. The capsules of the lipobed group patients compared with NRS group patients showed: a lower mean thickness (602.17 versus 670.43 µm; P = 0.013), a lower collagen fiber alignment (median value of angle deviation: 30.34 versus 18.38; P = 0.001), a lower immunohistochemical positivity for myofibroblasts (α-smooth muscle actin [α-SMA] expression: 12.5% versus 52.5%; P = 0.00), a higher immunohistochemical positivity for estrogen receptor-β (ER-β; 80% versus 20%; P = 0.00), and a lower immunohistochemical positivity for estrogen receptor-α (ER-α; 53.3% versus 16.7%; P = 0.00). The histological and immunohistochemical differences found are possibly due to alterations in the extracellular microenvironment determined by grafted fat.

来源:J Plast Reconstr Aesthet Surg,查看原文。版权归原作者所有。

引用

  1. Pagliara D, Vitagliano S, Mangialardi ML, et al. The role of fat grafting on contracted breast implant capsules: A retrospective comparative histological and immunohistochemical study. J Plast Reconstr Aesthet Surg. 2021. PMID: 34838502. doi:10.1016/j.bjps.2021.09.035