文献速递特殊人群用药

基于输液泵数据优化新生儿和婴儿持续输注标准化浓度

Optimizing standardized neonatal and infant continuous infusion concentrations based on intravenous infusion pump data.
PubMed 文献 · Am J Health Syst Pharm · 2025-01-01

PURPOSE: The study aimed to optimize standardized concentrations for neonatal and infant continuous infusions to enhance patient safety and reduce medication errors.…

要点

  • 分析4,179次给药后,8种药物无需调整,9种建议修改浓度或注射器规格。
  • 以呋塞米为例,优化浓度和注射器规格以适应最低输注速率并减少注射器更换。
  • 该方法可为新生儿和婴儿持续输注浓度的国家标准化提供基础。

核心结论

  • 基于实际输注泵使用数据和最佳实践推荐,可优化新生儿和婴儿持续输注的标准化浓度与注射器规格,以提升患者安全并减少用药错误。

主要发现

  • 应用排除标准后,共4,179次给药纳入分析。
  • 8种药物无需调整,9种药物建议修改浓度和注射器规格。
  • 以呋塞米为例,优化其浓度和注射器规格以适应最低输注速率并减少注射器更换。

临床怎么用

  • 临床可参考该框架,基于本机构输液泵使用数据评估并优化新生儿和婴儿持续输注的标准化浓度与注射器规格。

局限性

  • 不同机构间可能存在差异,该方法学可为全国标准化工作提供基础。
  • 未来研究应探索更广泛的数据整合和先进技术以进一步提升用药安全。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: The study aimed to optimize standardized concentrations for neonatal and infant continuous infusions to enhance patient safety and reduce medication errors. By analyzing actual utilization data and integrating best practice recommendations, a framework for optimal concentrations and syringe sizes was developed. METHODS: Three focus groups comprising pediatric and neonatal nurses, pharmacists, and physicians were conducted to identify best practices for infusion management. Twelve months of utilization data from Medfusion 4000 Wireless Syringe Infusion Pumps were collected for patients weighing less than 10 kg. Data were filtered based on specific criteria, and concentrations were optimized based on fluid percentage, syringe exchanges, and infusion rates. RESULTS: After applying exclusion criteria, 4,179 administrations were included for analysis. No changes were needed for 8 medications, while modifications were recommended for 9 others. Changes included adjustments to concentrations and syringe sizes to improve infusion practices and reduce errors. For example, furosemide's concentration and syringe size were optimized to accommodate minimum infusion rates and reduce syringe exchanges. CONCLUSION: The study highlights significant opportunities for optimizing standardized concentrations in neonatal and infant care. While variations may exist across institutions, the methodology provides a foundation for national standardization efforts. Future research should explore broader data integration and advanced technologies to further enhance medication safety.

来源:Am J Health Syst Pharm,查看原文。版权归原作者所有。

引用

  1. Moss AC, Morbitzer KA, Eckel SF, et al. Optimizing standardized neonatal and infant continuous infusion concentrations based on intravenous infusion pump data. Am J Health Syst Pharm. 2025. PMID: 40491174. doi:10.1093/ajhp/zxaf116

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。