2019年乳腺细针穿刺实践:美国病理学家学会全国调查结果
该研究分析了美国病理学家学会(CAP)2019年非妇科细胞病理学教育项目补充问卷,调查了国内和国际实验室的乳腺细针穿刺(FNA)实践。不同机构类型及国内外实验室在制片、辅助检查、固定时间报告等方面存在显著差异。
要点
- 仅54.5%的实验室有标准化报告系统,16.8%知晓横滨报告系统。
核心结论
- 首次CAP细胞病理学委员会调查揭示乳腺FNA实践在不同机构类型及国内外实验室间存在显著差异,为未来研究提供基线。
研究设计与样本
- 基于CAP乳腺FNA实践补充问卷,分发至参与2019年CAP非妇科细胞病理学教育项目的实验室,分析499份常规评估乳腺FNA的实验室数据。
主要发现
- 仅54.5%(271/497)的实验室有标准化报告系统,仅16.8%(82/488)知晓国际细胞学会横滨乳腺FNA活检细胞学报告系统。
- 不同机构类型在同时进行FNA和粗针活检的频率、操作人员等方面存在显著差异。
- 国内外实验室在玻片制备、辅助检查、固定时间报告、标准化/描述性诊断及横滨报告系统知晓度方面存在显著差异。
临床怎么用
- 病理科应关注乳腺FNA的标准化报告和辅助检查固定时间记录,并提高对横滨报告系统的认知。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
CONTEXT.—: The College of American Pathologists surveys provide national benchmarks of pathology practice for laboratories. OBJECTIVE.—: To investigate breast fine-needle aspiration (FNA) biopsy practice in domestic and international laboratories in 2019. DESIGN.—: We analyzed data from the College of American Pathologists Breast FNA Practice Supplemental Questionnaire that was distributed to laboratories participating in the 2019 College of American Pathologists Non-Gynecologic Cytopathology Education Program. RESULTS.—: Sixty-one percent (499 of 816) of respondent laboratories routinely evaluated breast FNAs. Cystic lesions were the most common indication, and radiologists primarily performed FNAs in most settings. Forty-five percent (220 of 491) of laboratories performed ancillary studies on breast FNA samples, but 33.8% (70 of 207) did not report fixation time for breast biomarker studies. Only 54.5% (271 of 497) of laboratories had a standardized reporting system and only 16.8% (82 of 488) were aware of the International Academy of Cytology Yokohama Breast FNA Biopsy Cytology Reporting System. There were significant differences among different types of institutions in several aspects of breast FNA practice, including frequency of concurrent FNA and core needle biopsy for the same lesion, primary personnel who performed the FNA, etc. Significant differences existed between domestic and international laboratories in slide preparation, ancillary studies, fixation time reporting, standardized/descriptive diagnosis, and International Academy of Cytology Yokohama Reporting System awareness. CONCLUSIONS.—: This is the first survey from the College of American Pathologists Cytopathology Committee to investigate breast FNA practices. The data reveal significant differences in breast FNA practice among different types of institutions and between domestic and international laboratories, and provide a baseline for future breast FNA studies in a variety of practice settings.
引用
- Li Z, Souers RJ, Tabbara SO, et al. Breast Fine-Needle Aspiration Practice in 2019: Results of a College of American Pathologists National Survey. Arch Pathol Lab Med. 2021. PMID: 33351901. doi:10.5858/arpa.2020-0408-CP
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。