CytoLyt固定胰腺FNA标本中腺泡细胞诱导的自溶频发
该研究对157例胰腺细针穿刺(FNA)细胞学样本进行盲法回顾,比较CytoLyt固定(CF-CBs)与福尔马林固定(FF-CBs)细胞块的自溶情况。结果显示,73%的胰腺CF-CBs存在显著自溶,而FF-CBs仅4%,非胰腺CF-CBs为12%,差异均具统计学意义。结论提示CytoLyt不适用于胰腺FNA固定,应避免使用。
要点
- 胰腺FNA的CytoLyt固定细胞块中73%出现显著自溶,远高于福尔马林固定的4%。
- 自溶主要累及腺泡细胞和/或肿瘤细胞,背景良性腺泡细胞亦可见。
- 病理医生和细胞技术员应避免将CytoLyt作为胰腺FNA的固定剂。
核心结论
- CytoLyt虽适用于非胰腺FNA,但对胰腺FNA是次优固定剂,多数病例出现组织/肿瘤自溶,影响形态学评估并可能影响免疫细胞化学染色。
研究设计与样本
- 对157例胰腺FNA细胞学样本进行盲法回顾,比较CytoLyt固定细胞块(CF-CBs)与福尔马林固定细胞块(FF-CBs)的自溶情况,并设非胰腺FNA的CF-CBs及4例配对CF-CBs和FF-CBs作为对照。
主要发现
- 85例胰腺CF-CBs中62例(73%)显示显著自溶,而46例FF-CBs中仅2例(4%)自溶(P < .0001)。
- 26例非胰腺CF-CBs中3例(12%)自溶,胰腺CF-CBs自溶率(73%)显著高于非胰腺CF-CBs(12%)(P < .0001)。
- 4例配对胰腺FNA中,所有CF-CBs均显示明显自溶,而配对的FF-CBs均无自溶。
- 23例(27%)无自溶的胰腺CF-CBs中,10例无腺泡细胞,7例细胞块仅见微小组织碎片。
关键数值与推荐
- 胰腺CF-CBs自溶率73%(62/85),FF-CBs自溶率4%(2/46),P < .0001。
- 非胰腺CF-CBs自溶率12%(3/26),与胰腺CF-CBs比较P < .0001。
临床怎么用
- 胰腺FNA标本应避免使用CytoLyt固定,优先选择10%福尔马林以保持组织形态和免疫细胞化学染色质量。
局限性
- 无自溶的胰腺CF-CBs中部分病例缺乏腺泡细胞或仅见微小组织碎片,可能低估自溶发生率。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Although 10% formalin is a standard preservative in pancreatic FNAs, the effect of CytoLyt on pancreatic tissue preservation has not been systematically explored. METHODS: Smears and cell blocks from CytoLyt-fixed (CF-CBs) and formalin-fixed (FF-CBs) pancreatic FNAs were blindly reviewed without knowledge of the fixative used, and the presence of tissue/tumor autolysis was noted. Controls included FF-CBs from pancreatic FNAs, CF-CBs from nonpancreatic FNAs, and 4 pancreatic FNAs with matched CF-CBs and FF-CBs. RESULTS: We found that 62 of 85 (73%) pancreatic FNAs with CF-CBs showed significant autolysis, which was most pronounced in acinar cells and/or tumor cells with benign acinar cells in the background, compared with 2 of 46 (4%) FF-CBs (P < .0001) and 3 of 26 (12%) CF-CBs from nonpancreatic FNAs (73% vs 12%; P < .0001). Of the 4 pancreatic FNAs with matched CF-CBs and FF-CBs, all 4 CF-CBs showed marked autolysis versus none of the matched FF-CBs. Of the 23 (27%) pancreatic FNAs with CF-CBs that did not show autolysis, 10 had no acinar cells, and 7 had only minute tissue fragments on CB. CONCLUSION: While CytoLyt is a useful fixative for nonpancreatic FNAs it is a suboptimal fixative for pancreatic FNAs and is associated with tissue/tumor autolysis in the majority of cases, influencing morphologic evaluation, and potentially immunocytochemical staining. Autolysis appears to be due to acinar enzymes whose effect is likely interrupted/inhibited by formalin fixation. Cytopathologists and cytotechnologists should be mindful of this pitfall and should avoid using CytoLyt as a fixative for pancreatic FNAs.
引用
- Alwelaie Y, Point du Jour KS, Pandya S, et al. Acinar cell induced autolysis is a frequent occurrence in CytoLyt-fixed pancreatic fine needle aspiration specimens: An analysis of 157 cytology samples. Cancer Cytopathol. 2020. PMID: 33136337. doi:10.1002/cncy.22378
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。