文献速递胸部病理细胞病理与分子病理

非小细胞肺癌细胞学与组织学标本PD-L1免疫染色一致性中的福尔马林固定作用

Formalin fixation for optimal concordance of programmed death-ligand 1 immunostaining between cytologic and histologic specimens from patients with non-small cell lung cancer.
PubMed 文献 · Cancer Cytopathol · 2020-10-27

该研究对67例非小细胞肺癌患者的细针穿刺细胞学与对应组织学标本进行配对比较,使用SP263与22C3抗体检测PD-L1。琼脂细胞块与组织块一致性较高,Cellient细胞块一致性仅一般至中等。醇类固定剂降低PD-L1免疫反应性,福尔马林固定后染色更高且与组织学更一致。

要点

  • 醇类固定细胞学标本可致PD-L1假阴性,福尔马林固定一致性更佳。
  • 琼脂细胞块与组织学PD-L1一致性较高,Cellient细胞块一致性一般至中等。
  • 醇类固定后追加福尔马林后固定,可在一定程度上恢复22C3染色。

核心结论

  • 醇类固定细胞学标本行PD-L1染色可能产生假阴性结果,福尔马林固定可获得更高且与组织学更一致的PD-L1免疫染色。
  • 醇类固定的不良影响可通过福尔马林后固定在一定程度上逆转。

研究设计与样本

  • 对67例非小细胞肺癌患者行肺切除/肺叶切除标本细针穿刺,采集配对组织学与细胞学样本。
  • 制备福尔马林固定琼脂细胞块或CytoLyt/PreservCyt固定Cellient细胞块,切片用SP263与22C3抗体染色并比较PD-L1评分。
  • 另用多种固定剂及递增固定时间处理表达PD-L1的人细胞系,比较免疫染色。

主要发现

  • 琼脂细胞块与组织块一致性分别为κ = 0.70和κ = 0.67。
  • Cellient细胞块与组织学一致性为κ = 0.28和κ = 0.49。
  • 醇类固定细胞系PD-L1免疫反应性低于福尔马林固定者。
  • 与SP263不同,醇类固定后追加福尔马林固定,22C3实验室自建检测与22C3 pharmDx染色强度得以保留。

关键数值与推荐

  • 琼脂细胞块与组织块PD-L1一致性κ = 0.70和κ = 0.67。
  • Cellient细胞块与组织学一致性κ = 0.28和κ = 0.49。

临床怎么用

  • 细胞学标本行PD-L1检测时优先采用福尔马林固定,以避免醇类固定导致的假阴性。
  • 醇类固定标本必要时可追加福尔马林后固定,但需注意抗体差异对结果的影响。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Immunohistochemical staining of programmed death-ligand 1 (PD-L1) is used to determine which patients with non-small cell lung cancer (NSCLC) may benefit most from immunotherapy. Therapeutic management of many patients with NSCLC is based on cytology instead of histology. In this study, concordance of PD-L1 immunostaining between cytology cell blocks and their histologic counterparts was analyzed. Furthermore, the effect of various fixatives and fixation times on PD-L1 immunoreactivity was studied. METHODS: Paired histologic and cytologic samples from 67 patients with NSCLC were collected by performing fine-needle aspiration on pneumonectomy/lobectomy specimens. Formalin-fixed, agar-based or CytoLyt/PreservCyt-fixed Cellient cell blocks were prepared. Sections from cell blocks and tissue blocks were stained with SP263 (standardized assay) and 22C3 (laboratory-developed test) antibodies. PD-L1 scores were compared between histology and cytology. In addition, immunostaining was compared between PD-L1-expressing human cell lines fixed in various fixatives at increasing increments in fixation duration. RESULTS: Agar cell blocks and tissue blocks showed substantial agreement (κ = 0.70 and κ = 0.67, respectively), whereas fair-to-moderate agreement was found between Cellient cell blocks and histology (κ = 0.28 and κ = 0.49, respectively). Cell lines fixed in various alcohol-based fixatives showed less PD-L1 immunoreactivity compared with those fixed in formalin. In contrast to SP263, additional formalin fixation after alcohol fixation resulted in preserved staining intensity using the 22C3 laboratory-developed test and the 22C3 pharmDx assay. CONCLUSIONS: Performing PD-L1 staining on cytologic specimens fixed in alcohol-based fixatives could result in false-negative immunostaining results, whereas fixation in formalin leads to higher and more histology-concordant PD-L1 immunostaining. The deleterious effect of alcohol fixation could be reversed to some degree by postfixation in formalin.

来源:Cancer Cytopathol,查看原文。版权归原作者所有。

引用

  1. Koomen BM, van der Starre-Gaal J, Vonk JM, et al. Formalin fixation for optimal concordance of programmed death-ligand 1 immunostaining between cytologic and histologic specimens from patients with non-small cell lung cancer. Cancer Cytopathol. 2020. PMID: 33108706. doi:10.1002/cncy.22383

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。