文献速递细胞病理与分子病理

米兰系统报告涎腺细胞病理学对多形性腺瘤和Warthin瘤诊断准确性的评估:一项国际多机构研究

Assessing the diagnostic accuracy for pleomorphic adenoma and Warthin tumor by employing the Milan System for Reporting Salivary Gland Cytopathology: An international, multi-institutional study.
PubMed 文献 · Cancer Cytopathol · 2020-08-07

该研究回顾性纳入4国11机构的1250例配对涎腺细针穿刺(FNA)和切除标本,按米兰系统(MSRSGC)分类,评估多形性腺瘤(PA)和Warthin瘤(WT)的诊断准确性。

要点

  • PA和WT的FNA诊断准确性高(95.1%和96.1%)。
  • 良性肿瘤类别中PA的ROM为3.0%,WT为1.3%。
  • SUMP类别中WT的ROM(18.8%)显著高于PA(2.7%)。

核心结论

  • PA和WT的FNA诊断准确性高。
  • SUMP类别中基底样肿瘤和嗜酸细胞样肿瘤的ROM存在差异。

研究设计与样本

  • 回顾性研究,检索4国11机构病理档案,纳入1250例配对FNA和切除标本。

主要发现

  • 共纳入1250例,其中PA 898例,WT 352例。
  • 良性肿瘤类别中PA的ROM为3.0%,WT为1.3%。
  • PA和WT的诊断准确性分别为95.1%和96.1%。

关键数值与推荐

  • 良性肿瘤类别ROM:PA 3.0%,WT 1.3%。
  • 诊断准确性:PA 95.1%,WT 96.1%。

临床怎么用

  • FNA对PA和WT诊断准确性高,可支持临床决策。
  • SUMP类别中WT的ROM较高,需注意鉴别基底样和嗜酸细胞样肿瘤。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The Milan System for Reporting Salivary Gland Cytopathology (MSRSGC) has established distinct diagnostic categories for reporting cytopathological findings, and each is associated with a defined risk of malignancy (ROM). However, the ROM is applied at the overall category level and is not specific for particular morphological entities within a category. Here, the diagnostic performance of the MSRSGC for pleomorphic adenoma (PA) and Warthin tumor (WT) is reported. METHODS: The pathology archives of 11 institutions from 4 countries were retrospectively searched to identify all salivary gland fine-needle aspiration (FNA) biopsies with a differential or definitive diagnosis of PA or WT and all resection specimens with a diagnosis of PA or WT; only paired cases were included. All FNA diagnoses were retrospectively classified according to the MSRSGC. RESULTS: A total of 1250 cases met the inclusion criteria, and they included 898 PA cases and 352 WT cases. The ROM in the benign neoplasm category was 3.0% and 1.3% for cases with a differential or definitive diagnosis of PA and WT, respectively. The ROM in the salivary gland neoplasm with uncertain malignant potential (SUMP) category was 2.7% and 18.8% for PA and WT, respectively (P = .0277). The diagnostic accuracy for PA and WT was 95.1% and 96.1%, respectively. CONCLUSIONS: The diagnostic accuracy for PA and WT on FNA is high. Furthermore, these findings highlight the difference in the ROMs associated with 2 specific differential diagnoses in the SUMP category: basaloid neoplasms and oncocytoid neoplasms.

来源:Cancer Cytopathol,查看原文。版权归原作者所有。

引用

  1. Allison DB, Smith AP, An D, et al. Assessing the diagnostic accuracy for pleomorphic adenoma and Warthin tumor by employing the Milan System for Reporting Salivary Gland Cytopathology: An international, multi-institutional study. Cancer Cytopathol. 2020. PMID: 32767837. doi:10.1002/cncy.22339

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。