文献速递细胞病理与分子病理胸部病理

细胞离心上清液与FFPE组织用于靶向NGS检测的比较

Comparison of cytocentrifugation supernatant fluid and formalin-fixed paraffin-embedded tissue for targeted next-generation sequencing.
PubMed 文献 · Cancer Cytopathol · 2019-04-01

该研究评估细胞离心后上清液(SN)提取的DNA和RNA用于下一代测序(NGS)检测临床相关生物标志物的可行性。对30例经FFPE细胞块(CB)证实为恶性的支气管内细针穿刺冲洗液,在去除细胞沉淀后收集SN并提取DNA/RNA,用内部NGS实体瘤聚焦检测组合检测,并与对应FFPE样本结果比较。结果显示30例样本全部检测成功,SN与FFPE标本的变异结果100%一致,变异等位基因频率高度相关(相关系数0.93),提示SN是NGS检测的有价值来源。

要点

  • 细胞离心上清液可用于NGS检测,30例样本全部检测成功
  • SN与FFPE标本的变异结果100%一致
  • SN与FFPE的变异等位基因频率高度相关(相关系数0.93)

核心结论

  • 细胞离心上清液是NGS检测的有价值来源,与FFPE相当且可减少因细胞块材料不足导致的检测失败率。

研究设计与样本

  • 研究纳入30例经FFPE细胞块证实为恶性的支气管内细针穿刺冲洗液,去除细胞沉淀后收集细胞离心上清液并提取DNA和RNA,用内部NGS实体瘤聚焦检测组合检测,与对应FFPE样本结果比较。

主要发现

  • 30例样本全部检测成功。
  • SN与对应FFPE标本的变异结果100%一致,包括50个单核苷酸变异、9个拷贝数扩增、3个结构变异和2个插入缺失。
  • SN中突变与对应FFPE细胞块中突变的变异等位基因频率高度相关,相关系数为0.93。

临床怎么用

  • 在FFPE细胞块制备过程中,常规丢弃的细胞离心上清液可保留用于NGS检测,以补充组织材料并降低检测失败率。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The emergence of less invasive procedures coupled with the growth of molecular testing have created a need for clinical laboratories to optimize workflows to enable tissue preservation and ancillary testing. In the preparation of formalin-fixed paraffin-embedded cell blocks (FFPE CBs), there is a cytocentrifugation step for cell pellet extraction that results in postcentrifugation supernatant fluid (SN). This SN, which in most routine workflows is discarded, has been suggested to contain adequate cellular material for molecular testing. In the current study, the authors describe the use of DNA and RNA extracted from SN for the detection of clinically relevant biomarkers by next-generation sequencing (NGS). METHODS: After cell pellet removal, cytocentrifugation SN from 30 endobronchial fine-needle aspiration rinses that were positive for malignancy on FFPE CB were collected. DNA and RNA were extracted from the SN and tested using an in-house NGS Solid Tumor Focus Assay. The NGS results were compared with findings from corresponding FFPE samples. RESULTS: Testing was successful in all 30 samples. There was 100% concordance between variants observed in the SN and corresponding FFPE specimens, which included 50 single-nucleotide variants, 9 copy number amplifications, 3 structural variants, and 2 indels. Furthermore, there was excellent correlation (correlation coefficient, 0.93) between the variant allele frequency of mutations observed in SN compared with that noted in corresponding FFPE CBs. CONCLUSIONS: Cytocentrifugation SN is a valuable source for NGS, is comparable to FFPE that preserves tissue for other ancillary testing, and can reduce the failure rate of testing that may result from insufficient material being available in the CB.

来源:Cancer Cytopathol,查看原文。版权归原作者所有。

引用

  1. Janaki N, Harbhajanka A, Michael CW, et al. Comparison of cytocentrifugation supernatant fluid and formalin-fixed paraffin-embedded tissue for targeted next-generation sequencing. Cancer Cytopathol. 2019. PMID: 30933438. doi:10.1002/cncy.22126

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。