文献速递细胞病理与分子病理

一种可自动化判断甲状腺细针穿刺样本充足性的方法

An Automatable Method for Determining Adequacy of Thyroid Fine-Needle Aspiration Samples.
PubMed 文献 · Arch Pathol Lab Med · 2018-10-24

该研究开发了一种基于荧光标记和计算机图像分析的自动化系统,用于评估甲状腺细针穿刺样本的充足性,并使用全部抽吸样本。研究采用12例已知诊断病例训练算法,11例用于验证,将算法评分与细胞病理学家对ThinPrep玻片的盲法评分比较。结果显示算法在验证组中正确识别8/8例充足样本和2/3例不充足样本,1例被误判为不充足。

要点

  • 荧光标记联合图像分析可自动化评估甲状腺细针穿刺样本充足性。
  • 验证组中算法正确识别8/8例充足样本和2/3例不充足样本。
  • 该方法利用全部样本,可能避免快速现场评估的样本损耗问题。

核心结论

  • 使用荧光标记技术结合计算机图像分析自动化评估甲状腺细针穿刺样本充足性是可行的。

研究设计与样本

  • 研究使用12例既往诊断病例作为训练集,11例病例用于图像分析算法的验证。
  • 样本经荧光染色后用荧光显微镜成像,由图像分析算法评估充足性,随后制备ThinPrep玻片并由细胞病理学家盲法评分,比较标准与计算机结果。

主要发现

  • 算法在训练集12例中优化后应用于11例测试病例。
  • 测试组8例充足样本全部被算法正确评为充足。
  • 测试组3例不充足样本中2例被算法正确评为不充足,1例被错误判定为不充足。

临床怎么用

  • 该自动化方法有望用于甲状腺细针穿刺样本的充足性评估,减少对快速现场评估的依赖。

局限性

  • 验证样本量较小(11例),仍需更大规模研究确认算法性能。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

CONTEXT.—: Thyroid nodules are a common clinical problem. Cytologic evaluation via fine-needle aspiration is often employed in the diagnostic workup, and rapid on-site assessment of adequacy can help ensure an adequate sample is obtained. However, rapid on-site assessment of adequacy only examines part of the sample, a part that may not then be available for ancillary testing. Moreover, the procedure is time-consuming and poorly reimbursed. OBJECTIVE.—: To develop an automatable fluorescence-based image analysis system for assessing the adequacy of thyroid fine-needle aspirations that uses the entire aspirated sample. DESIGN.—: There were 12 previously diagnosed cases that served as a training set, and 11 cases were used for validation of an image analysis algorithm. The samples were fluorescently stained and imaged using a fluorescent microscope. The images were assessed for adequacy by an image analysis algorithm. Following image analysis, a ThinPrep slide was prepared and blindly scored by a cytopathologist. The standard and computer-derived results were then compared. RESULTS.—: The algorithm was optimized using the 12 cases in the training set and then applied to the 11 test cases. A total of 8 of 8 adequate samples in the test group were correctly scored as adequate, and 2 of 3 cases that were inadequate were correctly scored as inadequate by the algorithm. One case was erroneously designated as not adequate by the algorithm. CONCLUSIONS.—: Our results demonstrate the feasibility of automating thyroid adequacy assessment using a fluorescent labeling technique followed by computer image analysis.

来源:Arch Pathol Lab Med,查看原文。版权归原作者所有。

引用

  1. Schmolze DB, Fischer AH. An Automatable Method for Determining Adequacy of Thyroid Fine-Needle Aspiration Samples. Arch Pathol Lab Med. 2018. PMID: 30354272. doi:10.5858/arpa.2018-0072-OA

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。