文献速递细胞病理与分子病理

344380份体液细胞学能力验证应答的性能特征分析

Performance Characteristics of Body Fluid Cytology Analysis of 344 380 Responses From the College of American Pathologists Interlaboratory Comparison Program in Nongynecologic Cytopathology.
PubMed 文献 · Arch Pathol Lab Med · 2017-10-19

该研究分析美国病理学家学会非妇科细胞学室间比对项目中5102张体液细胞学玻片的参与者应答,总体一般类别(GC)符合率为95.2%,GC类型、参与者类型和制片类型与GC符合率显著相关(P < .001)。恶性病例GC符合率高于良性病例,细胞技术员GC符合率优于病理医生,ThinPrep玻片GC符合率最高。参与者类型、体液类型、制片类型和参与者判读与参考诊断(RD)符合率显著相关(P < .001),心包液RD符合率最低。

要点

  • 总体GC符合率95.2%,恶性病例高于良性病例。
  • 细胞技术员GC符合率优于病理医生,但病理医生RD符合率更优。
  • 心包液RD符合率最低,尤其正常或反应性病例。

核心结论

  • 体液细胞学判读具有挑战性,其中心包液相关病例的参考诊断符合率最低。
  • 多种制片类型联合使用有助于困难病例的准确诊断。

研究设计与样本

  • 分析CAP非妇科细胞学室间比对项目中5102张玻片的参与者应答。
  • 采用非线性混合模型分析一般类别(GC)和参考诊断(RD)符合率。

主要发现

  • 总体GC符合率为95.2%。
  • GC类型、参与者类型和制片类型与GC符合率显著相关(P < .001)。
  • 恶性病例GC符合率高于良性病例,细胞技术员GC符合率优于病理医生,ThinPrep玻片GC符合率最高。
  • 参与者类型、体液类型、制片类型和参与者判读与RD符合率显著相关(P < .001),病理医生RD符合率优于细胞技术员。
  • 心包液RD符合率最低,尤其正常或反应性病例;改良Giemsa染色对淋巴瘤和造血系统恶性肿瘤表现最佳;小细胞癌GC符合率最高,且胸水RD符合率高于腹水;腺癌GC和RD符合率均最高。

临床怎么用

  • 判读体液细胞学时应关注心包液等低符合率标本类型。
  • 困难病例可联合使用多种制片类型以提高诊断准确性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

CONTEXT: - Body fluid cytology is an important diagnostic tool used to identify various conditions. However, an accurate diagnosis in this setting can sometimes be challenging. OBJECTIVE: - To identify the performance characteristics of body fluid cytology by analyzing participant responses from the College of American Pathologists Interlaboratory Comparison Program in Nongynecologic Cytopathology. DESIGN: - Participant responses from 5102 slides were analyzed for concordance to the general category (GC) and to the reference diagnosis (RD). Nonlinear mixed models were used to analyze concordance. RESULTS: - The overall GC concordance was 95.2%. The GC type, participant type, and preparation type were significantly associated with GC concordance ( P < .001). Concordance for malignant cases was higher than it was for benign cases. Cytotechnologists had better GC concordance compared to pathologists. ThinPrep (Hologic, Marlborough, Massachusetts) slides had the highest GC concordance. Participant type, fluid type, preparation type, and participant interpretation were significantly associated with RD concordance ( P < .001). Pathologists performed better than cytotechnologists did for RD concordance. Pericardial fluid had the lowest RD concordance, especially for cases with normal or reactive findings. Modified Giemsa-stained slides performed best for lymphoma and hematopoietic malignancy. Small cell carcinoma had the highest GC concordance, and its RD concordance was higher in pleural than in peritoneal fluids. Adenocarcinoma showed the highest concordance rates for both GC and RD. CONCLUSIONS: - This study illustrates the challenges associated with interpreting body fluid cytology, particularly in pericardial fluid, and the factors that may affect accurate diagnoses. The results also highlight the value of using multiple preparation types in challenging cases.

来源:Arch Pathol Lab Med,查看原文。版权归原作者所有。

引用

  1. Tabatabai ZL, Nayar R, Souers RJ, et al. Performance Characteristics of Body Fluid Cytology Analysis of 344 380 Responses From the College of American Pathologists Interlaboratory Comparison Program in Nongynecologic Cytopathology. Arch Pathol Lab Med. 2017. PMID: 29048220. doi:10.5858/arpa.2016-0509-CP

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。