文献速递细胞病理与分子病理神经与头颈病理

细针穿刺与冰冻切片评估恶性甲状腺结节的比较

Fine-Needle Aspiration Versus Frozen Section in the Evaluation of Malignant Thyroid Nodules in Patients With the Diagnosis of Suspicious for Malignancy or Malignancy by Fine-Needle Aspiration.
PubMed 文献 · Arch Pathol Lab Med · 2017-01-01

该研究回顾性分析单中心3年内细针穿刺(FNA)诊断为可疑恶性或恶性并接受术中冰冻切片(FS)的甲状腺切除术病例,比较FNA与FS对恶性甲状腺病变的评估效能。结果显示,FNA恶性组FS假阴性率约10%,FNA可疑恶性组FS良性者最终病理超半数恶性,提示FNA恶性者不应行FS,可疑恶性者行FS需谨慎解读。

要点

  • FNA诊断为恶性时,FS评估可能导致约10%假阴性,不应行FS。
  • FNA诊断为可疑恶性时,FS良性者最终病理超半数恶性,需谨慎解读FS结果。
  • FS在可疑恶性组中应用可能更有依据,但仍需结合最终病理。

核心结论

  • FNA恶性类别不应行FS,因FS评估可能导致10%假阴性。
  • FNA可疑恶性类别行FS可能更有依据,但FS良性者超半数最终病理为恶性,需谨慎。

研究设计与样本

  • 单中心3年回顾性分析,纳入FNA诊断为可疑恶性或恶性并接受甲状腺切除术中FS的病例。
  • 共5832例甲状腺切除术,其中1265例有FNA和FS结果。

主要发现

  • FNA可疑恶性306例中,FS良性/不确定32例(10.5%),可疑14例(4.6%),恶性260例(84.9%);最终病理恶性率分别为56.3%(18/32)、64.3%(9/14)、100%(260/260)。
  • FNA恶性821例中,FS良性/不确定82例(10.0%),可疑36例(4.4%),恶性703例(85.6%);最终病理恶性率分别为96.4%(79/82)、97.2%(35/36)、99.9%(702/703)。

临床怎么用

  • FNA诊断为恶性时,不推荐行术中FS评估。
  • FNA诊断为可疑恶性时,可考虑FS,但FS良性结果需谨慎,因超半数最终为恶性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

CONTEXT: - The Bethesda System for Reporting Thyroid Cytopathology recommends against the use of intraoperative frozen section (FS) during lobectomy of a thyroid nodule with a fine-needle aspiration (FNA) diagnosis of malignant. Bethesda recommendations for FS in the FNA category of suspicious for malignancy (SFM) is less well-defined. In some institutions in China, FS examination is performed during lobectomy even for FNA-proven malignant cases. OBJECTIVE: - -To compare the efficacy of FNA versus FS in the evaluation of malignant thyroid lesions. DESIGN: - A 3-year retrospective analysis from a single institution was performed on cases with an FNA diagnosis of SFM or malignant with subsequent FS examination during thyroidectomy. The results of FNA and FS findings were compared to the final thyroidectomy pathology. RESULTS: - -A total of 5832 thyroidectomy procedures were performed: 1265 cases had FNA and FS results available. Fine-needle aspiration gave a diagnosis of SFM to 306 cases and a diagnosis of malignant to 821 cases. Of the SFM cases, 10.5% (32 of 306) had benign/indeterminate, 4.6% (14 of 306) suspicious, and 84.9% (260 of 306) malignant FS results. Final pathology showed 56.3% (18 of 32), 64.3% (9 of 14), and 100% (260 of 260) malignancy rates, respectively. For the malignant FNA group, 10.0% (82 of 821) had benign/indeterminate, 4.4% (36 of 821) suspicious, and 85.6% (703 of 821) malignant FS results. The final pathology showed 96.4% (79 of 82), 97.2% (35 of 36), and 99.9% (702 of 703) malignancy rates, respectively. CONCLUSIONS: - Frozen section should not be performed for the malignant FNA category because FS evaluation may result in 10% falsely negative findings. Performing FS for SFM may be better justified; however, more than half of FS cases read as benign in this category had malignant final pathology. Therefore, caution should be taken for FS results even in the SFM group.

来源:Arch Pathol Lab Med,查看原文。版权归原作者所有。

引用

  1. Ye Q, Woo JS, Zhao Q, et al. Fine-Needle Aspiration Versus Frozen Section in the Evaluation of Malignant Thyroid Nodules in Patients With the Diagnosis of Suspicious for Malignancy or Malignancy by Fine-Needle Aspiration. Arch Pathol Lab Med. 2017. PMID: 28447904. doi:10.5858/arpa.2016-0305-OA

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。