文献速递细胞病理与分子病理

全切片成像用于甲状腺细针穿刺快速评估的多读者前瞻性研究

Utility of whole-slide imaging for rapid evaluation of thyroid FNA: A multireader prospective study.
PubMed 文献 · Cancer Cytopathol · 2025-01-01

该前瞻性多读者研究评估了全切片图像(WSI)用于甲状腺细针穿刺活检(FNAB)快速现场评估(ROSE)的可行性,以判断标本满意度和Bethesda初步分类,并与传统光学显微镜(LM)比较。共评估98例超声引导下甲状腺FNAB,5名细胞病理学家在2周洗脱期后分别用WSI和LM评估。结果显示WSI与LM的读者内一致性极好(κ=0.86-0.95),读者间一致性中等(WSI κ=0.48,LM κ=0.56),WSI判读时间显著更长(p<.0001)。

要点

  • WSI用于甲状腺FNA的ROSE可行,读者内一致性极好(κ=0.86-0.95)。
  • WSI与LM的读者间一致性均为中等(κ=0.48 vs 0.56)。
  • Bethesda I和VI类一致性最高,III-V类最低。

核心结论

  • WSI是甲状腺FNAB快速现场评估中替代光学显微镜的可行方案,读者内一致性高,读者间一致性相当。

研究设计与样本

  • 前瞻性多读者研究,评估98例超声引导下甲状腺FNAB病例。
  • 涂片经巴氏和Diff-Quik染色,使用Leica Aperio CS2扫描仪以×20放大扫描。
  • 5名细胞病理学家先用WSI评估标本满意度和Bethesda分类,2周洗脱期后用光学显微镜评估。

主要发现

  • 共扫描463张玻片,平均扫描时间5.48分钟。
  • 23%的判读请求z轴堆叠,14%请求×40放大。
  • WSI与LM的读者内一致性极好(κ=0.86-0.95)。
  • 读者间一致性WSI为中等(κ=0.48),LM为中等(κ=0.56)。
  • WSI判读时间显著长于LM(p<.0001)。

关键数值与推荐

  • Bethesda I和VI类一致性最高,III-V类最低。
  • WSI质量在大多数病例中可接受。

临床怎么用

  • WSI可用于甲状腺FNA的ROSE,判断标本满意度和初步Bethesda分类。
  • 对高倍放大和z轴堆叠的需求有限,支持其实际应用。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Rapid on-site evaluation (ROSE) of thyroid fine-needle aspiration biopsy (FNAB) improves diagnostic adequacy and facilitates ancillary molecular testing. In this prospective, multireader study, the authors evaluated the feasibility of using whole-slide images (WSIs) for ROSE to determine specimen adequacy and preliminary categorization (according to The Bethesda System for Reporting Thyroid Cytopathology [Bethesda]) of image-guided thyroid FNABs compared with conventional light-microscopic (LM) examination of the same specimens in a referral cancer center. METHODS: The authors evaluated 98 ultrasound-guided thyroid FNAB cases. Smears were stained with Papanicolaou and Diff-Quik and were scanned at ×20 magnification using a Leica Aperio CS2 scanner. Five cytopathologists evaluated specimen adequacy and Bethesda categorization using WSI followed by LM assessment after a 2-week washout. Intraobserver and interobserver agreements were calculated using Cohen and Fleiss kappa (κ) statistics. Scan time, interpretation time, and the need for ×40 magnification or z stacking were recorded. RESULTS: In total, 463 slides were scanned, with mean scan time of 5.48 minutes. WSI quality was acceptable in most cases. Z stacking and ×40 magnification were requested in 23% and 14% of reviews, respectively. Intrareader agreement between WSI and LM examination was excellent (κ = 0.86-0.95). Inter-reader agreement was moderate for both WSI (κ = 0.48) and LM examination (κ = 0.56). Concordance was highest for Bethesda categories I and VI and lowest for categories III-V. Interpretation with WSI took significantly longer than with LM examination (p < .0001). CONCLUSIONS: WSI is a feasible alternative to LM examination for ROSE of thyroid FNABs, with high intrareader agreement and comparable inter-reader agreement. The limited need for high magnification and z stacking supports its practical utility.

来源:Cancer Cytopathol,查看原文。版权归原作者所有。

引用

  1. Ahmed MS, Klippel-Almaraz D, Amin SE, et al. Utility of whole-slide imaging for rapid evaluation of thyroid FNA: A multireader prospective study. Cancer Cytopathol. 2025. PMID: 40889104. doi:10.1002/cncy.70046

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。