本研究针对非小细胞肺癌患者,比较Genexus全自动核酸提取与手动提取FNA上清液的性能,并使用50基因Oncomine Precision Assay GX panel进行分子检测。结果显示自动提取将手动操作时间从120分钟降至30分钟,自动NGS工作流程总周转时间为24小时,质控指标与手动法相当。

要点

  • FNA上清液可用于NGS分子检测,自动与手动提取质控指标相当。
  • 自动提取将手动操作时间从120分钟降至30分钟。
  • 自动NGS工作流程从标本接收到结果总周转时间为24小时。

核心结论

  • 基于FNA上清液的自动化NGS工作流程可实现24小时周转时间,提供快速可靠的分子结果。

研究设计与样本

  • 研究比较Genexus全自动核酸提取与手动提取FNA上清液,样本来自50例非小细胞肺癌患者。
  • 使用50基因Oncomine Precision Assay GX panel进行分子检测,并与配对组织样本的NGS结果比较。

主要发现

  • 自动Genexus纯化系统处理42例,手动提取处理8例,质控指标相当。
  • 自动提取中位总核酸产量为1230 ng(范围18-17720 ng),手动提取为1068 ng(范围777-1740 ng)。
  • 50例提取样本中对26例进行NGS:手动提取7例,自动提取19例,两种提取方法的NGS质控指标相当。
  • 自动NGS工作流程从标本接收到检测结果的总周转时间为24小时。

临床怎么用

  • FNA上清液可作为细胞学液体活检样本用于NGS分子检测。
  • 自动化提取可减少手动操作时间并缩短周转时间,有助于及时临床决策。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Genomic profiling is essential in the management of non-small cell lung cancer. However, this may often be challenging because of limited cytological tissue and extended turnaround time (TAT) for next-generation sequencing (NGS). This study aims to describe a rapid TAT workflow for molecular profiling using fine-needle aspiration (FNA) supernatants. METHODS: A fully automated total nucleic acid extraction using the Genexus Integrated System was compared to a manual extraction using FNA supernatants from 50 patients with non-small cell lung cancer. Molecular profiling using the 50 gene Oncomine Precision Assay GX panel was performed and NGS results were compared with those of paired tissue samples. RESULTS: The FNA samples processed using the automated Genexus purification system (n = 42) and the manual extraction method (n = 8) showed comparable quality control metrics with a median total nucleic acid yield of 1230 ng (18-17720 ng) and 1068 ng (777-1740 ng), respectively. The Genexus purification system reduced the hands-on time from 120 to 30 minutes, enhancing workflow efficiency and decreasing the overall TAT. Of the 50 samples extracted, NGS was performed on 26 samples: seven via manual extraction and 19 using automated extraction. NGS quality control metrics were also comparable between both extraction methods. The overall TAT of the automated NGS workflow from specimen received to test result was 24 hours, providing rapid and reliable molecular results for timely clinical decision-making and improved patient outcomes.