米兰报告系统在腮腺粗针活检中的应用
该研究探索将米兰唾液腺细胞病理学报告系统应用于腮腺粗针活检(CNB)的可行性。回顾分析100例腮腺CNB,其中32例有后续切除、52例有同期细针穿刺(FNA),20例同时有FNA和后续切除;63%的CNB提供了具体诊断,有随访切除的18例准确率达94%。结论认为类米兰系统用于腮腺CNB可行,可区分肿瘤风险(RON)和恶性风险(ROM),CNB可评估组织结构特征以助更具体诊断。
要点
- 类米兰系统可用于腮腺粗针活检,区分RON与ROM。
- 63%的腮腺CNB可给出具体诊断。
- 有随访切除的具体诊断准确率达94%。
核心结论
- 类米兰报告系统应用于腮腺粗针活检可行,可区分肿瘤风险与恶性风险。
- 粗针活检可评估组织结构特征,在某些病例中有助更具体诊断。
研究设计与样本
- 回顾性研究,检索实验室信息系统2010至2021年腮腺粗针活检病例。
- 分析100例腮腺粗针活检,其中32例有后续切除,52例有同期细针穿刺,20例同时有细针穿刺和后续切除。
- 另建立腮腺细针穿刺且有手术随访的队列以比较两者性能。
主要发现
- 100例腮腺粗针活检中63例(63%)提供了具体诊断。
- 有随访切除的18例具体诊断准确率为94%。
关键数值与推荐
- 采用类米兰报告系统对粗针活检报告进行归类。
- 利用有随访切除的病例计算细针穿刺和粗针活检各米兰分类的肿瘤风险与恶性风险。
临床怎么用
- 可参照类米兰系统对腮腺粗针活检进行标准化报告并区分肿瘤风险与恶性风险。
- 粗针活检的组织结构评估有助于在部分病例中作出更具体诊断。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: The Milan system for reporting salivary gland cytopathology was developed by an international group of experts and first published in 2018 with the goal to standardise reporting of salivary gland aspirates. Seven categories with distinct risks of malignancy were proposed. Core needle biopsies (CNB) of salivary glands are also common, but reporting lacks standardisation. Here we explore the feasibility of a Milan-like reporting system on CNB of the parotid gland. METHODS AND RESULTS: Our laboratory information system was searched for parotid gland CNBs from 2010 to 2021. Reports were translated into a Milan-like reporting system. When available, CNB findings were correlated with cytology and resection specimens. In order to compare the performance of CNB with fine-needle aspirations (FNA), we established a second cohort of cases consisting of parotid FNA with surgical follow-up. The risk of neoplasia (RON) and risk of malignancy (ROM) was calculated for FNA and CNB Milan categories using cases with follow-up resection. We analysed 100 cases of parotid gland CNB. Of these cases, 32 underwent subsequent resection, while 52 had concurrent FNA. A total of 20 cases had concurrent FNA and underwent follow-up resection. In 63 (63%) cases, a specific diagnosis was provided on CNB, with 18 cases undergoing follow-up resection having an accuracy rate of 94%. CONCLUSIONS: This study confirms the feasible of using a Milan-like system in the setting of parotid gland CNB with differentiation in RON and ROM. CNB allows assessment of architectural features that may allow more specific diagnoses in some cases.
引用
- Israel AK, Griffith CC. Application of the Milan system for reporting salivary gland cytopathology to core needle biopsies of the parotid gland. Histopathology. 2024. PMID: 38773807. doi:10.1111/his.15200
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。