文献速递细胞病理与分子病理

国际浆膜液细胞病理学报告系统诊断准确性的系统评价与Meta分析

Diagnostic accuracy of International System for Reporting Serous Fluid Cytopathology: A systematic review and meta-analysis in malignancy diagnosis.
PubMed 文献 · Cancer Cytopathol · 2024-04-13

以「非典型及以上」为阳性时敏感度77%、特异度95%;以「可疑恶性及以上」为阳性时敏感度57%、特异度100%;以「恶性」为阳性时敏感度70%、特异度99%,AUC为85%至89.5%。

要点

  • ISRSFC各分类的汇总恶性风险与诊断准确性首次通过Meta分析量化。
  • 「可疑恶性」和「恶性」类别对识别恶性具有重要诊断价值。
  • 「良性」类别在排除恶性中发挥作用。

核心结论

  • 该Meta分析强调ISRSFC在浆膜液细胞学报告中的准确性。
  • 「可疑」和「恶性」类别对识别恶性具有诊断重要性,「良性」类别在排除恶性中发挥作用。

研究设计与样本

  • 系统检索PubMed/MEDLINE和Embase,使用QUADAS-2工具评估偏倚风险。
  • 排除不合格样本后,对不同的阳性截断点进行敏感度和特异度的Meta分析。

主要发现

  • 以「非典型及以上」为阳性时,敏感度77%(95%CI 68%-84%),特异度95%(95%CI 93%-97%)。
  • 以「可疑恶性及以上」为阳性时,敏感度57%(95%CI 49%-65%),特异度100%(95%CI 99%-100%)。
  • 以「恶性」为阳性时,敏感度70%(95%CI 60%-77%),特异度99%(95%CI 98%-99%)。
  • 每个截断点的汇总AUC范围为85%至89.5%。

临床怎么用

  • ISRSFC可用于浆膜液细胞学报告的标准化诊断。
  • 「可疑恶性」和「恶性」类别有助于识别恶性,「良性」类别有助于排除恶性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

This study conducts the first meta-analysis to assess the aggregated risk of malignancy associated with each category of the International System for Reporting Serous Fluid Cytopathology (ISRSFC) for reporting serous effusion cytology, while also evaluating diagnostic accuracy. PubMed/MEDLINE and Embase were systematically searched using the keywords "(pleural, peritoneal, and pericardial effusions) AND (serous effusion cytology) OR (International System for Reporting Serous Fluid Cytopathology)". Articles underwent risk of bias assessment using the QUADAS-2 tool. After excluding inadequate samples, a meta-analysis determined sensitivity and specificity for different cutoff points, including "atypical considered positive," "suspicious of malignancy considered positive," and "malignant considered positive." Summary receiver operating characteristic curves assessed diagnostic accuracy, and the diagnostic odds ratio was pooled. Sixteen retrospective cross-sectional studies, totaling 19,128 cases, were included. Sensitivity and specificity for the "atypical and higher risk categories" considered positive were 77% (95% confidence interval [CI], 68%-84%) and 95% (95% CI, 93%-97%) respectively. For the "suspicious for malignancy and higher risk categories" considered positive, sensitivity and specificity were 57% (95% CI, 49%-65%) and 100% (95% CI, 99%-100%) respectively. Sensitivity and specificity for the "malignant" category considered positive for malignancy were 70% (95% CI, 60%-77%) and 99% (95% CI, 98%-99%), respectively. The pooled area under the curve ranged from 85% to 89.5% for each cutoff. This meta-analysis underscores the ISRSFC's accuracy in reporting serous fluid cytology. It emphasizes the diagnostic importance of the "suspicious" and "malignant" categories in identifying malignancy, and the role of the "benign" category in ruling out malignancy.

来源:Cancer Cytopathol,查看原文。版权归原作者所有。

引用

  1. Ahuja S, Ahuja R, Pandey S, et al. Diagnostic accuracy of International System for Reporting Serous Fluid Cytopathology: A systematic review and meta-analysis in malignancy diagnosis. Cancer Cytopathol. 2024. PMID: 38613789. doi:10.1002/cncy.22822