悉尼系统淋巴结细胞病理学的数字化检查:一项国际多机构研究
该研究评估了悉尼系统在淋巴结细针穿刺细胞学中的观察者间可重复性,15名细胞病理学家对85例病例进行数字阅片,共产生1275个诊断。结果显示与真实值几乎完全一致(中位加权Cohen κ=0.887),总体观察者间一致性中等(Fleiss κ=0.476),其中标本不足和恶性类别一致性较好,而可疑和非典型类别一致性极低。
要点
- 悉尼系统在淋巴结细胞学中总体观察者间一致性中等(Fleiss κ=0.476)。
- 标本不足和恶性类别一致性较好(κ=0.794和0.729)。
- 可疑和非典型类别一致性极低(κ=0.104和0.075)。
核心结论
- 悉尼系统在淋巴结细胞病理学报告中显示出足够的观察者间一致性。
- 数字显微镜是评估淋巴结细胞病理学标本的合适方法。
研究设计与样本
- 国际多机构研究,15名细胞病理学家来自8个国家12个机构。
- 对85例淋巴结细针穿刺细胞学病例进行数字阅片,共产生1275个诊断。
- 扫描了186张切片,染色包括Diff-Quik、巴氏和免疫细胞化学。
主要发现
- 与真实值的总体一致性几乎完美,中位加权Cohen κ=0.887(四分位距κ=0.210)。
- 观察者间总体一致性中等,Fleiss κ=0.476。
- 标本不足类别一致性较好(κ=0.794),恶性类别一致性较好(κ=0.729)。
- 良性类别一致性中等(κ=0.490)。
- 可疑类别一致性极低(κ=0.104),非典型类别一致性极低(κ=0.075)。
临床怎么用
- 悉尼系统可用于淋巴结细胞病理学的标准化报告,但需注意可疑和非典型类别的一致性较低。
- 数字显微镜可用于评估淋巴结细胞病理学标本。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: After a series of standardized reporting systems in cytopathology, the Sydney system was recently introduced to address the need for reproducibility and standardization in lymph node cytopathology. Since then, the risk of malignancy for the categories of the Sydney system has been explored by several studies, but no studies have yet examined the interobserver reproducibility of the Sydney system. METHODS: The authors assessed interobserver reproducibility of the Sydney system on 85 lymph node fine-needle aspiration cytology cases reviewed by 15 cytopathologists from 12 institutions in eight different countries, resulting in 1275 diagnoses. In total, 186 slides stained with Diff-Quik, Papanicolaou, and immunocytochemistry were scanned. A subset of the cases included clinical data and results from ultrasound examinations, flow cytometry immunophenotyping, and fluorescence in situ hybridization analysis. The study participants assessed the cases digitally using whole-slide images. RESULTS: Overall, the authors observed an almost perfect agreement of cytopathologists with the ground truth (median weighted Cohen κ = 0.887; interquartile range, κ = 0.210) and moderate overall interobserver concordance (Fleiss κ = 0.476). There was substantial agreement for the inadequate and malignant categories (κ = 0.794 and κ = 0.729, respectively), moderate agreement for the benign category (κ = 0.490), and very slight agreement for the suspicious (κ = 0.104) and atypical (κ = 0.075) categories. CONCLUSIONS: The Sydney system for reporting lymph node cytopathology shows adequate interobserver concordance. Digital microscopy is an adequate means to assess lymph node cytopathology specimens.
引用
- Caputo A, Fraggetta F, Cretella P, et al. Digital Examination of LYmph node CYtopathology Using the Sydney system (DELYCYUS): An international, multi-institutional study. Cancer Cytopathol. 2023. PMID: 37418195. doi:10.1002/cncy.22741
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。