文献速递细胞病理与分子病理神经与头颈病理

NR4A3荧光原位杂交在腺泡细胞癌细胞学与手术标本中的分析

NR4A3 fluorescence in situ hybridization analysis in cytologic and surgical specimens of acinic cell carcinoma.
PubMed 文献 · Hum Pathol · 2022-06-11

该研究在3家学术机构对52例腺泡细胞癌(含47例切除和5例细针穿刺,其中5对配对)及7例对照进行NR4A3分离探针FISH检测,8例检测失败。可评估病例中FISH阳性23/39,灵敏度59%,对照全部阴性,特异度100%,5对配对FNA/切除标本结果完全一致。

要点

  • NR4A3 FISH检测腺泡细胞癌灵敏度59%、特异度100%。
  • 配对FNA与切除标本FISH结果100%一致,支持细胞学应用。
  • 15%腺泡细胞癌FISH检测失败,需注意判读可行性。

核心结论

  • NR4A3重排驱动的上调是腺泡细胞癌中反复出现且特异的致癌事件。
  • NR4A3 FISH检测腺泡细胞癌的灵敏度为59%(23/39),特异度为100%(0/7)。

研究设计与样本

  • 使用NR4A3双色分离探针(ZytoVision,德国)在3家大型学术机构对腺泡细胞癌进行FISH检测。
  • 共分析52例腺泡细胞癌,包括47例切除标本和5例FNA(含5对配对FNA/切除),对照为5例非腺泡细胞癌涎腺肿瘤和2例涎腺炎。
  • NR4A3重排阳性定义为15%组织间期核出现阳性信号模式。
  • 8例腺泡细胞癌(15%,8/52)FISH检测失败。

主要发现

  • 23例腺泡细胞癌FISH阳性,灵敏度59%(23/39)。
  • 5对配对切除/FNA标本FISH结果100%一致(3例阳性,2例阴性)。
  • 所有非腺泡细胞癌对照FISH阴性,特异度100%(0/7)。

关键数值与推荐

  • NR4A3重排阳性判定阈值为15%组织间期核显示阳性信号模式。

临床怎么用

  • NR4A3 FISH可作为腺泡细胞癌诊断的辅助检测,尤其适用于细胞学样本。
  • FISH阴性不排除腺泡细胞癌,因灵敏度仅59%。
  • FISH检测失败率15%,判读时需评估标本可评估性。

局限性

  • 8例腺泡细胞癌FISH检测失败,可能影响灵敏度评估。
  • 对照样本量较小(非腺泡细胞癌5例、涎腺炎2例)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Acinic cell carcinoma (AciCC) may pose a diagnostic challenge, particularly on small biopsies and fine needle aspiration (FNA) because of its variable histology including potential high-grade transformation and its mimickers. Immunoreactivity with circumferential membranous staining for DOG1 can support the diagnosis of AciCC but is not entirely specific. A novel rearrangement t(4;9)(q13;q31) leading to up-regulation of nuclear receptor subfamily 4 group A member 3 (NR4A3) has been described in AciCC, is potentially detectable by fluorescence in situ hybridization (FISH) and may be useful in the evaluation for AciCC. Using NR4A3 Dual Color Break Apart Probe (ZytoVision, Germany) FISH was performed on AciCCs from 3 large academic institutions. NR4A3 rearrangement was defined as positive signal patterns in 15% of tissue interphase nuclei. Fifty-two AciCCs including 47 resections and 5 FNAs (including 5 paired FNA/resections) were analyzed. Five non-AciCC salivary gland tumors and 2 sialadenitis cases were used as controls. Eight AciCCs (15%; 8/52) failed FISH testing. FISH was positive in 23 AciCCs (sensitivity 59%, 23/39) with 100% concordance between 5 matched resection/FNAs (3 were positive for FISH and 2 were negative). FISH was negative in all non-AciCCs (specificity: 100%, 0/7). NR4A3 FISH has a sensitivity of 59% and specificity of 100% in detecting AciCC, which suggests that NR4A3 rearrangement-driven up-regulation is a recurrent, specific oncogenic event in AciCC, consistent with prior results. Hundred percent concordance between matched FNA/resection samples validates its potential utility on cytology samples.

来源:Hum Pathol,查看原文。版权归原作者所有。

引用

  1. Shi Q, Zhang B, Bsirini C, et al. NR4A3 fluorescence in situ hybridization analysis in cytologic and surgical specimens of acinic cell carcinoma. Hum Pathol. 2022. PMID: 35700750. doi:10.1016/j.humpath.2022.06.007

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。