文献速递运动医学创伤骨科

股四头肌腱骨块取材部位髌骨尺寸变异:评估安全取材范围的MRI研究

Patellar Size Variation at the Quadriceps Tendon-Bone Block Harvest Site: A Magnetic Resonance Imaging Study to Evaluate the Safe Zone for Harvesting a Sufficient Bone Block.
PubMed 文献 · Am J Sports Med · 2021-10-21

本研究对50名男性和50名女性(平均年龄29.4±7.9岁)的膝关节进行3.0-T MRI,测量股四头肌腱宽度、厚度及髌骨不同位点的高度和厚度。

要点

  • 骨块深度不超过髌骨厚度50%、长度小于髌骨高度50%且位于中线内侧时髌骨骨折风险最低。
  • 从中央区内侧半取材,锯片外缘置于中央区内侧缘,可安全获取长15mm、宽10mm、深8mm的骨块。
  • 该尺寸在所有白人男性和几乎全部身高>165cm的女性中可安全取材。

核心结论

  • 骨块深度不超过髌骨厚度50%、长度小于髌骨高度50%且位于中线内侧时,髌骨骨折风险最低。
  • 从中央区内侧半取材,锯片外缘置于中央区内侧缘,可安全获取长15mm、宽10mm、深8mm的骨块。

研究设计与样本

  • 描述性实验室研究,纳入50名男性和50名女性(平均年龄29.4±7.9岁),对膝关节行3.0-T磁共振成像。
  • 在股四头肌腱髌骨止点中三分之一中心及内外侧端点测量髌骨高度,在相应高度中点测量深度。

主要发现

  • 股四头肌腱平均宽度为49.0±7.6 mm,平均厚度为7.3±1.0 mm。
  • 髌骨内侧端点、中心、外侧端点的平均厚度分别为18.3±2.4、17.9±2.3、15.1±2.3 mm。
  • 髌骨内侧端点、中心、外侧端点的平均高度分别为35.1±4.1、36.7±4.2、35.1±3.9 mm。

关键数值与推荐

  • 骨块深度不超过髌骨厚度的50%,长度小于髌骨高度的50%,且位于中线内侧。
  • 从中央区内侧半取材,锯片外缘置于中央区内侧缘,可安全获取长15mm、宽10mm、深8mm的骨块。
  • 该尺寸在所有白人男性和几乎全部身高>165cm的女性中可安全取材。

临床怎么用

  • 术前可参考MRI测量的髌骨厚度和高度,个体化规划股四头肌腱骨块取材尺寸。
  • 取材时骨块深度不超过髌骨厚度50%、长度小于髌骨高度50%,并优先选择中线内侧位置。
  • 对身高>165cm的女性及所有白人男性,可考虑安全获取长15mm、宽10mm、深8mm的骨块。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Quadriceps tendon (QT) autografts with and without a bone block are the least studied and least used options for anterior cruciate ligament reconstruction surgery. In particular, there is a lack of literature describing patellar anatomy. Until now, guidelines for patellar bone block harvesting have been based solely on personal experience. In this study, we intended to derive recommendations from physical regularities and objective criteria. PURPOSE: To determine the maximal, individual-related length and depth of the bone block that can be safely harvested and to provide guidelines to help surgeons make decisions on graft choice. STUDY DESIGN: Descriptive laboratory study. METHODS: The study group consisted of 50 male participants and 50 female participants (mean age, 29.4 ± 7.9 years) who underwent 3.0-T magnetic resonance imaging of their knee. Patellar height was determined at the center of the middle third of the QT insertion on the patella and the medial and lateral endpoints; the depth was measured at the midpoints of the respective heights. RESULTS: The mean width of the QT and the mean thickness were 49.0 ± 7.6 and 7.3 ± 1.0 mm, respectively. The mean patellar thickness in reference to the medial endpoint, the center, and the lateral endpoint was 18.3 ± 2.4, 17.9 ± 2.3, and 15.1 ± 2.3 mm, respectively, whereas the mean patellar height was 35.1 ± 4.1, 36.7 ± 4.2, and 35.1 ± 3.9 mm. In general, the tendon and patellar dimensions were significantly larger in male participants than in female participants (P = .016). CONCLUSION: Bone block harvesting, with its depth not exceeding 50% of the patellar thickness and its length accounting for <50% of the patellar height, poses the least risk for a patellar fracture when located medial to midline. If the bone block is excised from the medial half of the central area (the latter is defined by the middle third of the QT insertion), with the outer edge of the saw positioned at the medial border of the central area, a graft of 15 mm length, 10 mm width, and 8 mm depth can be safely harvested in all White male participants and almost all female participants taller than 165 cm, according to our findings. CLINICAL RELEVANCE: This is the first study presenting recommendations for patellar bone block harvesting at the quadriceps tendon insertionbased on physical regularities and objective criteria and not on personal experience.

来源:Am J Sports Med,查看原文。版权归原作者所有。

引用

  1. Negrin LL, Zeitler C, Hofbauer M, et al. Patellar Size Variation at the Quadriceps Tendon-Bone Block Harvest Site: A Magnetic Resonance Imaging Study to Evaluate the Safe Zone for Harvesting a Sufficient Bone Block. Am J Sports Med. 2021. PMID: 34672796. doi:10.1177/03635465211049226

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。