文献速递关节外科

一体式陶瓷衬垫髋臼组件与传统模块化非骨水泥髋臼组件的骨盆骨丢失比较:2年随机临床试验

Does a Monoblock Acetabular Component With a Ceramic Liner Cause More Pelvic Bone Loss Than a Conventional Modular Cementless Acetabular Component? A 2-Year Randomized Clinical Trial.
PubMed 文献 · J Arthroplasty · 2021-09-04

本研究将髋关节置换患者随机分为模块化金属对聚乙烯髋臼组件组(n=46)和羟基磷灰石钛涂层一体式陶瓷对陶瓷髋臼组件组(n=40),通过双能X线吸收法测量骨密度并随访2年。结果显示两组骨密度无显著差异,但一体式组完全骨-假体接触无透亮线的比例更高(93% vs 67%,P<.001),模块化组件是透亮线的独立预测因素(OR 19.1,P=.007)。

要点

  • 一体式陶瓷对陶瓷髋臼组件与模块化金属对聚乙烯组件在2年内骨密度无显著差异。
  • 一体式组完全骨-假体接触无透亮线的比例显著高于模块化组(93% vs 67%,P<.001)。
  • 模块化组件是出现透亮线的独立预测因素(OR 19.1,P=.007),无因髋臼松动翻修病例。

核心结论

  • 多孔涂层模块化与羟基磷灰石涂层一体式髋臼组件在短期随访中均显示良好临床结果,像素级骨密度无差异。
  • 使用大直径股骨头的一体式装置与模块化装置相比,未对局部骨环境产生不良影响。

研究设计与样本

  • 随机临床试验,参与者随机接受模块化金属对聚乙烯髋臼组件(n=46)或羟基磷灰石钛涂层一体式陶瓷对陶瓷髋臼组件(n=40)。
  • 术前及术后进行影像学评估,术后及2年随访期间采用双能X线吸收法区域自由分析测量骨密度。

主要发现

  • 两组基线及随后2年骨密度无显著差异。
  • 随访时完全骨-假体接触无透亮线在模块化装置中观察到26例(67%),在一体式装置中观察到37例(93%),P<.001。
  • 模块化装置是透亮线的独立预测因素(OR 19.1,P=.007)。
  • 无因髋臼松动行翻修手术的病例。

关键数值与推荐

  • 完全骨-假体接触无透亮线比例:模块化组67%(26/46),一体式组93%(37/40),P<.001。
  • 模块化装置预测透亮线的OR为19.1,P=.007。

临床怎么用

  • 一体式陶瓷对陶瓷髋臼组件在2年随访中未显示对骨盆骨密度不利,且透亮线发生率更低。
  • 模块化金属对聚乙烯组件与透亮线风险独立相关,临床选择时需考虑。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Ceramic-on-ceramic bearings permit the use of large femoral head size while maintaining a favorable effect on wear rates. However, because of increased device rigidity, periprosthetic bone quality could be negatively affected due to stress shielding. The purpose of this study is to assess pelvic periprosthetic bone remodeling around a monoblock ceramic-on-ceramic acetabular component compared to that around a conventional modular metal-on-polyethylene device. METHODS: Participants were randomized to receive hip replacement using either a porous-coated, modular metal-on-polyethylene acetabular component (n = 46) or a hydroxyapatite and titanium-coated monoblock shell with an integrated ceramic-on-ceramic bearing (n = 40). Radiographic assessments were completed preoperatively and postoperatively, and measurements of bone mineral density (BMD) using dual-energy X-ray absorptiometry with region free analysis were performed postoperatively and over 2-years of follow-up. RESULTS: There was no significant difference in BMD between the 2 groups at baseline or over the following 2 years. At follow-up, complete shell-to-bone contact without a radiolucent line was observed in 26 (67%) of the modular devices and in 37 (93%) of monoblock (P < .001). The modular device was an independent predictor of radiolucent lines (odds ratio 19.1, P = .007). No cases underwent revision surgery for acetabular loosening. CONCLUSION: Both the porous-coated modular and hydroxyapatite-coated monoblock acetabular components showed successful clinical results at short-term follow-up with no difference in pixel-level BMD. Using a large head monoblock device does not appear to be associated with an adverse effect on the local bone environment when compared to a modular device. NCT: NCT01558752.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Fischman D, Mahatma MM, Slullitel P, et al. Does a Monoblock Acetabular Component With a Ceramic Liner Cause More Pelvic Bone Loss Than a Conventional Modular Cementless Acetabular Component? A 2-Year Randomized Clinical Trial. J Arthroplasty. 2021. PMID: 34649747. doi:10.1016/j.arth.2021.08.033

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。