手术入路与股骨假体类型对全髋关节置换翻修率的影响
基于澳大利亚骨科协会国家关节置换登记系统2015年至2019年数据,分析48,716例因骨关节炎行初次全髋关节置换并使用5种最常见非骨水泥股骨柄的病例。前入路与后入路全因累积翻修率无差异,但前入路股骨柄松动翻修率(HR 2.00;95%CI 1.48-2.69;p<0.001)和骨折翻修率(HR 1.78;95%CI 1.34-2.35;p<0.001)更高,且前入路下不同股骨柄间翻修率差异明显。
要点
- 前入路与后入路全因翻修率无差异,但前入路股骨柄松动和骨折翻修风险更高。
- 前入路下Quadra-H全因翻修率高于Polarstem(HR 1.49)和Corail(HR 1.31)。
- 后入路下不同非骨水泥股骨柄间翻修率差异较小。
核心结论
- 前入路全髋关节置换的股骨柄松动和骨折翻修率高于后入路,且前入路下不同股骨柄间翻修结果差异更大。
研究设计与样本
- 共纳入48,716例全髋关节置换,其中前入路22,840例,后入路25,876例。
- 主要结局为全因累积翻修百分比及股骨柄松动和骨折的累积翻修百分比。
- 证据等级为治疗性III级。
主要发现
- 前入路与后入路全因累积翻修百分比无差异。
- 前入路松动翻修率高于后入路(HR 2.00;95%CI 1.48-2.69;p<0.001)。
- 前入路骨折翻修率高于后入路(HR 1.78;95%CI 1.34-2.35;p<0.001)。
- 前入路下Quadra-H全因累积翻修百分比高于Polarstem(HR 1.49;95%CI 1.16-1.91;p=0.002)。
- 前入路下Quadra-H全因累积翻修百分比高于Corail(HR 1.31;95%CI 1.00-1.70;p=0.0478)。
关键数值与推荐
- 前入路松动翻修风险为后入路的2.00倍(HR 2.00;95%CI 1.48-2.69;p<0.001)。
- 前入路骨折翻修风险为后入路的1.78倍(HR 1.78;95%CI 1.34-2.35;p<0.001)。
- 前入路下Quadra-H较Polarstem全因翻修风险高49%(HR 1.49;95%CI 1.16-1.91;p=0.002)。
- 前入路下Quadra-H较Corail全因翻修风险高31%(HR 1.31;95%CI 1.00-1.70;p=0.0478)。
临床怎么用
- 选择前入路行全髋关节置换时,应关注股骨柄松动和骨折翻修风险,并考虑股骨柄类型对翻修率的影响。
- 前入路下Quadra-H的全因翻修率高于Polarstem和Corail,假体选择时可参考该登记数据。
局限性
- 本研究为登记系统数据分析,证据等级为治疗性III级。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Compared with other total hip arthroplasty (THA) approaches, the anterior approach has an increased rate of revision for femoral-sided complications, and certain stems may increase this risk. The present study aimed to assess the outcome of THA by surgical approach, according to the femoral stem utilized in the procedure. METHODS: Data from the Australian Orthopaedic Association National Joint Replacement Registry were analyzed for patients undergoing primary THA for osteoarthritis via the anterior or posterior approach with use of 1 of 5 of the most common cementless femoral stems from January 2015 to December 2019. The primary outcome measures were the cumulative percent revision (CPR) for all causes and for femoral stem loosening and fracture. The CPR was compared between THAs performed via the anterior and posterior approaches for all stems and for each individual femoral stem, as well as between individual femoral stems for each approach. RESULTS: The study included 48,716 THAs performed with use of cementless stems, of which 22,840 utilized an anterior approach and 25,876 utilized a posterior approach. There was no difference in the all-cause CPR between the anterior and the posterior approach, but the anterior approach had a higher CPR for loosening (hazard ratio [HR], 2.00; 95% confidence interval [CI], 1.48 to 2.69; p < 0.001) and fracture (HR, 1.78; 95% CI, 1.34 to 2.35; p < 0.001). There was apparent variation in the CPR across the different cementless stems when an anterior approach was utilized. The Quadra-H (Medacta) had a higher all-cause CPR when compared with the Polarstem (Smith & Nephew; HR, 1.49; 95% CI, 1.16 to 1.91; p = 0.002) and Corail (DePuy Synthes; HR, 1.31; 95% CI, 1.00 to 1.70; p = 0.0478). Variation was less apparent with the posterior approach. CONCLUSIONS: THAs performed via the anterior approach had higher rates of revision for femoral stem loosening and fracture, with greater variation in outcomes between individual stems. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.