双十字稳定型全膝关节置换的迁移与可诱导位移:间隙平衡与测量截骨技术的随机对照试验
本研究为单盲前瞻性随机对照试验,将71例患者分配至间隙平衡(GB)或测量截骨(MR)组,最终GB组31例、MR组25例,均植入JOURNEY II™ BCS假体。采用放射立体测量分析评估假体迁移与可诱导位移,随访至术后2年。结果显示两组在胫骨或股骨迁移及可诱导位移上均无差异(P > .05),两种技术均安全有效。
要点
- GB与MR组在胫骨或股骨迁移的任何测量上均无差异(P > .05)。
- 两组胫骨迁移从基线至6个月均低于0.5 mm,6个月至1年及1–2年均低于0.2 mm。
- 两组可诱导位移无差异(P > .05),BCS假体迁移风险与行业标准相当。
核心结论
- 间隙平衡与测量截骨技术在BCS全膝关节置换的假体迁移和可诱导位移上无差异。
- BCS假体的迁移风险与行业标准相当,两种手术技术均安全有效。
研究设计与样本
- 患者均植入JOURNEY II™ BCS假体,采用放射立体测量分析评估迁移与可诱导位移。
- 随访时间为术后2周基线、6周、3个月、6个月、1年及2年。
主要发现
- GB与MR组在胫骨或股骨迁移的任何测量上均无差异(P > .05)。
- 两组胫骨迁移从基线至6个月均低于0.5 mm,6个月至1年及1–2年均低于0.2 mm。
- 两组可诱导位移无差异(P > .05)。
临床怎么用
- 对于使用JOURNEY II™ BCS假体的全膝关节置换,GB与MR技术均可选择,迁移风险相当。
- 术后2年内假体迁移和可诱导位移在两种技术下均较低,支持其安全性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The goal of this study is to investigate the migration and inducible displacement of a bicruciate-stabilized (BCS) total knee arthroplasty implanted using gap balancing (GB) or measured resection (MR) surgical techniques. We hypothesized equal migration and displacement between the techniques. METHODS: The study is a single-blinded, prospective, randomized controlled trial, with allocation of 71 patients to either GB or MR groups. Fifteen patients were withdrawn, resulting in 31 patients in the GB group and 25 in the MR group. Patients received the JOURNEY II™ BCS implant. Migration and inducible displacement were evaluated using radiostereometric analysis and patient examinations were performed at a 2-week baseline, and at 6 weeks, 3 months, 6 months, 1 year, and 2 years postoperation. RESULTS: No differences (P > .05) existed between GB and MR groups for any measurement of tibial or femoral migration. Both groups had tibial migrations below 0.5 mm from baseline to 6 months, and below 0.2 mm from both 6 months to 1 year and 1-2 years postoperation. No differences (P > .05) were found between GB and MR groups for inducible displacement. CONCLUSION: No differences were found in implant migration or inducible displacement between GB and MR groups. The BCS implant can be expected to have migration risks on par with industry standards and both surgical techniques are safe and effective options for implantation of this implant design.
引用
- Broberg JS, Vasarhelyi EM, Lanting BA, et al. Migration and Inducible Displacement of the Bicruciate-Stabilized Total Knee Arthroplasty: A Randomized Controlled Trial of Gap Balancing and Measured Resection Techniques. J Arthroplasty. 2021. PMID: 34710566. doi:10.1016/j.arth.2021.10.010
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。