放射性透亮线不影响高交联聚乙烯骨水泥髋臼假体的长期生存
回顾性分析170例患者187髋全髋置换,使用高交联聚乙烯骨水泥髋臼假体,平均随访13.0年。髋臼假体无菌性松动翻修为零,假体生存率98.2%,21.2%髋出现放射性透亮线,但均无进展且不影响生存与临床评分。
要点
- 高交联聚乙烯骨水泥髋臼假体10年以上生存率98.2%,无无菌性松动翻修。
- 21.2%髋出现放射性透亮线,平均术后1.7年,均无进展且不影响假体生存。
- 股骨头自体植骨不负面影响髋臼假体生存或透亮线出现。
核心结论
- 高交联聚乙烯骨水泥髋臼假体在全髋置换中10年以上临床结果优异。
- 放射性透亮线均无进展,其出现不影响假体生存和临床评分。
研究设计与样本
- 回顾性研究,纳入两家医院170例患者共187髋全髋置换,随访至少10年。
- 所有干预使用同一组合的高交联聚乙烯骨水泥髋臼假体与钛合金股骨柄。
主要发现
- 平均随访13.0年(范围10.0至16.3年)。
- 135髋(72.2%)行股骨头自体植骨。
- 1髋因深部感染取出髋臼假体,无因无菌性松动翻修。
- 38髋(21.2%)检测到放射性透亮线,平均术后1.7年(范围1个月至6年)出现。
- 放射性透亮线均无进展,且与生存率和临床评分无显著关联;无植骨者透亮线更常见。
关键数值与推荐
- 主要终点(任何原因髋臼假体翻修)Kaplan-Meier生存率为98.2%(95%CI 88.6%至99.8%)。
- 次要终点(放射性透亮线出现)Kaplan-Meier生存率为79.3%(95%CI 72.8%至84.6%)。
临床怎么用
- 高交联聚乙烯骨水泥髋臼假体可预期良好长期生存,放射性透亮线出现无需干预。
- 股骨头自体植骨不增加翻修风险或放射性透亮线风险。
局限性
- 回顾性研究设计,仅纳入两家医院患者。
- 随访时间范围为10.0至16.3年,样本量187髋。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: We aimed to evaluate the long-term outcome of highly cross-linked polyethylene (HXLPE) cemented acetabular components and assess whether any radiolucent lines (RLLs) which arose were progressive. METHODS: We retrospectively reviewed 170 patients who underwent 187 total hip arthroplasties at two hospitals with a minimum follow-up of ten years. All interventions were performed using the same combination of HXLPE cemented acetabular components with femoral stems made of titanium alloy. Kaplan-Meier survival analysis was performed for the primary endpoint of acetabular component revision surgery for any reason and secondary endpoint of the appearance of RLLs. RLLs that had appeared once were observed over time. We statistically assessed potential relationships between RLLs and a number of factors, including the technique of femoral head autografting and the Japanese Orthopaedic Association score. RESULTS: The mean follow-up period was 13.0 years (10.0 to 16.3). Femoral head autografting was performed on 135 hips (72.2%). One acetabular component was retrieved because of deep infection. No revision was performed for the aseptic acetabular loosening. The Kaplan-Meier survival curve for the primary and secondary endpoints were 98.2% (95% confidence interval (CI) 88.6% to 99.8%) and 79.3% (95% CI 72.8% to 84.6%), respectively. RLLs were detected in 38 hips (21.2%), at a mean of 1.7 years (1 month to 6 years) postoperatively. None of the RLLs were progressive, and the presence of RLLs did not show a significant association with the survival and clinical score. RLLs were more frequently observed in hips without femoral head autografts than in those with autografts. CONCLUSION: The use of HXLPE cemented acetabular components in total hip arthroplasty demonstrated excellent clinical outcomes after ten years, and no RLLs were progressive, and their presence did not affect the outcome. Femoral head autografting did not negatively impact the acetabular component survival or the appearance of RLLs. Cite this article: Bone Joint J 2021;103-B(10):1604-1610.
引用
- Takaoka Y, Goto K, Tamura J, et al. Radiolucent lines do not affect the longevity of highly cross-linked polyethylene cemented components in total hip arthroplasty. Bone Joint J. 2021. PMID: 34587810. doi:10.1302/0301-620X.103B10.BJJ-2020-2298.R2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。