全髋关节置换术前脊柱影像筛查的成本效果
本研究采用马尔可夫决策模型,比较全髋关节置换术前常规脊柱影像筛查与不筛查的成本效果。筛查组中僵硬/过度活动脊柱患者假定使用双动头假体,结果显示筛查策略终身成本更低且质量调整生命年更高,11年时成为优势策略。
要点
- 术前脊柱影像筛查较不筛查终身成本更低且QALY更高。
- 筛查策略在术后5年达到成本效果,11年时成为优势策略。
- 当SHS患病率>1.9%、筛查成本<$925或双动头溢价<$2850时筛查仍为优势策略。
核心结论
- 全髋关节置换术前脊柱影像筛查发现僵硬/过度活动脊柱患者并指导双动头假体使用,较不筛查成本更低且更有效,应考虑纳入标准术前检查。
研究设计与样本
- 马尔可夫决策模型,比较常规术前脊柱影像筛查与不筛查,对象为有或无僵硬/过度活动脊柱的患者。
主要发现
- 筛查策略终身成本为$12,515,QALY为16.91;不筛查成本为$13,331,QALY为16.77。
- 筛查策略在术后5年达到成本效果,11年时成为优势策略。
关键数值与推荐
- 以每增加一个QALY支付$100,000作为成本效果阈值。
- 敏感性分析中,若SHS患病率>1.9%、筛查成本<$925、双动头假体较常规假体溢价<$2850,筛查仍为优势策略。
临床怎么用
- 对拟行全髋关节置换的患者,可考虑术前进行坐位和站立位腰椎侧位影像筛查僵硬/过度活动脊柱,以指导髋臼杯安放或双动头假体选择。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The risk of instability, dislocation, and revision following total hip arthroplasty (THA) is increased in patients with abnormal spinopelvic mobility. Seated and standing lateral lumbar spine imaging can identify patients with stiff/hypermobile spine (SHS) to guide interventions such as changes in acetabular cup placement or use of a dual-mobility hip construct aimed at reducing dislocation risk. METHODS: A Markov decision model was created to compare routine preoperative spinal imaging (PSI) to no screening in patients with and without SHS. Screened patients with SHS were assumed to receive dual-mobility hardware while those without SHS and nonscreened patients were assumed to receive conventional THA. Cost-effectiveness was determined by estimating the incremental cost-effectiveness ratio. Effectiveness measured as quality-adjusted life years (QALYs), with $100,000 per additional QALY as the threshold for cost-effectiveness. Sensitivity analyses were performed to determine the robustness of the base-case result. RESULTS: The screening strategy with PSI had a lifetime cost of $12,515 and QALY gains of 16.91 compared with no-screening ($13,331 and 16.77). The PSI strategy reached cost-effectiveness at 5 years and was dominant (ie, less costly and more effective) at 11 years following THA. In sensitivity analyses, PSI remained the dominant strategy if prevalence of SHS was >1.9%, the cost of PSI was <$925, and the cost of dual-mobility hardware exceeded the cost of conventional hardware by <$2850. CONCLUSION: Screening patients for SHS prior to THA with PSI is both less costly and more effective and should be considered as part of standard presurgical workup.
引用
- Nikkel LE, Tran L, Jennings JM, et al. Cost-Effectiveness of Preoperative Spinal Imaging Before Total Hip Arthroplasty. J Arthroplasty. 2021. PMID: 34592356. doi:10.1016/j.arth.2021.09.016
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。