磁控生长棒与传统生长棒治疗≥90°严重早发性脊柱侧凸的配对比较:治疗后2年中期报告
本研究基于前瞻性收集的国际数据库进行回顾性分析,纳入44例≥90°严重早发性脊柱侧凸(EOS)患儿接受磁控生长棒(MCGR)治疗,并与病因、年龄和性别匹配的传统生长棒(TGR)患者比较。2年随访显示,MCGR组主弯矫正显著优于TGR组(52° vs 66°,p=0.001),且无计划翻修生存率更高(91% vs 71%,p<0.005)。MCGR组EOSQ-24肺功能域评分更优,结论支持MCGR治疗严重EOS可提供更好的主弯矫正并减少无计划翻修。
要点
- MCGR治疗≥90°严重EOS在2年随访时主弯矫正显著优于TGR(52° vs 66°,p=0.001)。
- MCGR组2年无计划翻修生存率显著高于TGR组(91% vs 71%,p<0.005)。
- MCGR组EOSQ-24肺功能域评分更优,其余EOSQ-24评分无显著差异。
核心结论
- 对于严重(≥90°)早发性脊柱侧凸,MCGR在2年随访时提供显著更好的主弯矫正且无计划翻修显著少于TGR。
研究设计与样本
- 回顾性分析前瞻性收集的国际数据库,纳入44例≥90°严重EOS患儿接受MCGR治疗,并与病因、年龄和性别匹配的TGR患者比较,随访2年。
主要发现
- MCGR组与TGR组术前主弯平均均为104°,2年随访时分别为52°和66°(p=0.001)。
- MCGR组与TGR组T1-T12高度术前分别为155 mm和152 mm,2年随访分别为202 mm和192 mm(p=0.088)。
- Kaplan-Meier分析显示2年无计划翻修生存率MCGR组为91%,TGR组为71%(p<0.005)。
- MCGR组EOSQ-24肺功能域2年评分优于TGR组,EOSQ-24其他评分组间无显著差异。
关键数值与推荐
- 严重EOS定义为主弯≥90°。
- 2年随访主弯矫正MCGR组52°、TGR组66°(p=0.001)。
- 2年无计划翻修生存率MCGR组91%、TGR组71%(p<0.005)。
临床怎么用
- 对于≥90°严重EOS,MCGR可作为TGR的替代选择,以改善主弯矫正并降低无计划翻修风险。
局限性
- 本研究为回顾性设计,样本量44例,随访仅2年,为中期报告。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Severe early-onset scoliosis (EOS) is managed surgically but represents a challenge due to limited implant fixation points, large curve size, and fragile patients with comorbidities. Magnetically controlled growing rods (MCGRs) have the advantage of avoiding surgical intervention for routine lengthening, but their ability to address severe EOS has not been studied, to our knowledge. METHODS: A retrospective review of a prospectively collected international database identified 44 children with severe (≥90°) EOS treated with MCGRs who met our study criteria. Etiology, age, and sex-matched patients treated with traditional growing rods (TGRs) were identified from the same database. Patients were evaluated at a 2-year follow-up. No patients with vertically expandable prosthetic titanium ribs (VEPTRs) were included. The health-related quality of life was evaluated with the 24-Item Early Onset Scoliosis Questionnaire (EOSQ-24). RESULTS: The mean preoperative major coronal curve was 104° in the MCGR group and 104° in the TGR group. At the 2-year follow-up, the mean major coronal curves were 52° and 66° (p = 0.001), respectively. The mean T1-T12 heights were 155 mm and 152 mm preoperatively and 202 mm and 192 mm at the 2-year follow-up (p = 0.088). According to Kaplan-Meier analysis, the 2-year unplanned-revision-free survival was 91% in the MCGR group and 71% in the TGR group (p < 0.005). The 2-year score in the EOSQ-24 pulmonary function domain was better in the MCGR group. There were no other significant differences in the EOSQ-24 scores between the groups. CONCLUSIONS: MCGRs for severe EOS provided significantly better major curve correction with significantly fewer unplanned revisions than TGRs at a 2-year follow-up. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
引用
- Saarinen AJ, Sponseller PD, Andras LM, et al. Matched Comparison of Magnetically Controlled Growing Rods with Traditional Growing Rods in Severe Early-Onset Scoliosis of ≥90°: An Interim Report on Outcomes 2 Years After Treatment. J Bone Joint Surg Am. 2022. PMID: 34644282. doi:10.2106/JBJS.20.02108
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。