脊柱手术中经颅运动诱发电位基线波形导出不良病例的特征:日本脊柱外科及相关研究学会监测委员会前瞻性多中心研究
该前瞻性多中心研究纳入2017年4月至2020年3月16个脊柱中心3625例脊柱手术患者,探讨经颅运动诱发电位多通道监测中所有肌肉基线波形导出不良的病例特征。结果显示基线波形导出不良率为2%,与较高体重、体重指数、胸椎病变、术前MMT<3运动障碍、高风险手术及后纵韧带骨化手术显著相关。
要点
- 脊柱手术中Tc-MEP多通道监测基线波形导出不良率为2%。
- 胸椎病变、OPLL手术及术前MMT<3运动障碍者基线导出不良风险更高。
- 导出不良病例中34%术中可导出波形,拇展肌导出率最高。
核心结论
- 脊柱手术中Tc-MEP多通道监测基线波形导出不良率为2%,胸椎病变、OPLL、术前严重运动障碍及高风险手术者更易发生。
研究设计与样本
- 前瞻性多中心研究,纳入2017年4月至2020年3月16个脊柱中心3625例脊柱手术患者,平均年龄60.1岁,女1886例、男1739例。
主要发现
- 3625例中颈、胸、腰椎病变分别占50%、33%、17%,术前无运动障碍、MMT≥3和MMT<3分别占70%、24%、6%。
- 高风险手术1540例(43%),基线波形导出不良73例(2%)。
- 导出不良与较高体重、体重指数、胸椎病变、MMT<3运动障碍、高风险手术(42/1540[2.7%] vs. 31/2085[1.5%],P<0.05)及OPLL手术显著相关。
- 25例导出不良病例(34%)术中出现波形导出,拇展肌导出率最高。
临床怎么用
- 对胸椎病变、OPLL及术前严重运动障碍患者,宜采用多模式IONM并从远端肢体肌肉(包括拇展肌)导出多通道波形。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
STUDY DESIGN: Prospective multicenter study. OBJECTIVE: The purpose of the study is to examine cases with poor baseline waveform derivation for all muscles in multichannel monitoring of transcranial motor-evoked potentials (Tc-MEPs) in spine surgery. SUMMARY OF BACKGROUND DATA: Intraoperative neuromonitoring (IONM) is useful for identifying neurologic deterioration during spinal surgery. Tc-MEPs are widely used for IONM, but some cases have poor waveform derivation, even in multichannel Tc-MEP monitoring. METHODS: The subjects were 3625 patients (mean age 60.1 years, range 4-95; 1886 females, 1739 males) who underwent Tc-MEP monitoring during spinal surgery at 16 spine centers between April 2017 and March 2020. Baseline Tc-MEPs were recorded from the deltoid, abductor pollicis brevis, adductor longus, quadriceps femoris, hamstrings, tibialis anterior, gastrocnemius, and abductor hallucis (AH) muscles after surgical exposure of the spine. RESULTS: The 3625 cases included cervical, thoracic, and lumbar lesions (50%, 33% and 17%, respectively) and had preoperative motor status of no motor deficit, and motor deficit with manual muscle testing (MMT) ≥3 and MMT <3 (70%, 24% and 6%, respectively). High-risk surgery was performed in 1540 cases (43%). There were 73 cases with poor baseline waveform derivation (2%), and this was significantly associated with higher body weight, body mass index, thoracic lesions, motor deficit of MMT <3, high-risk surgery (42/1540 [2.7%] vs. 31/2085 [1.5%], P < 0.05), and surgery for ossification of the posterior longitudinal ligament (OPLL). Intraoperative waveform derivation occurred in 25 poor derivation cases (34%) and the AH had the highest rate. CONCLUSION: The rate of poor baseline waveform derivation in spine surgery was 2% in our series. This was significantly more likely in high-risk surgery for thoracic lesions and OPLL, and in cases with preoperative severe motor deficit. In such cases, it may be preferable to use multiple modalities for IONM to derive multichannel waveforms from distal limb muscles, including the AH.Level of Evidence: 3.
引用
- Kobayashi K, Imagama S, Ando K, et al. Characteristics of Cases with Poor Transcranial Motor-evoked Potentials Baseline Waveform Derivation in Spine Surgery: A Prospective Multicenter Study of the Monitoring Committee of the Japanese Society for Spine Surgery and Related Research. Spine (Phila Pa 1976). 2021. PMID: 34714796. doi:10.1097/BRS.0000000000004074
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。