文献速递脊柱外科骨质疏松与代谢性骨病

腰椎CT测量Hounsfield单位评估骨密度的系统综述

Efficacy of Hounsfield Units Measured by Lumbar Computer Tomography on Bone Density Assessment: A Systematic Review.
PubMed 文献 · Spine (Phila Pa 1976) · 2021-08-30

该系统综述纳入18项队列研究共5307例患者,比较CT测量的Hounsfield单位(HU)与双能X线吸收法(DXA)的T值在预测腰椎骨密度中的价值。骨质疏松患者平均HU值范围为54.7至130,骨量减少为78.8至146,正常为120.8至230;推断诊断骨质疏松的HU区间为90.9至138.7(95%CI,P<0.001)。结论认为CT的HU值有望用于骨质疏松诊断阈值,但需前瞻性大样本研究进一步验证。

要点

  • 骨质疏松患者腰椎CT的HU均值范围为54.7至130。
  • 八项研究通过ROC曲线确定骨质疏松诊断阈值,AUC为0.66至0.96。
  • 推断诊断骨质疏松的HU区间为90.9至138.7(95%CI,P<0.001)。

核心结论

  • 现有数据支持通过CT测量HU值建立骨质疏松诊断阈值的可行性。
  • 需要前瞻性大样本研究来更稳健地推断基于CT量化骨密度作为筛查试验的可能性及其预后价值。

研究设计与样本

  • 系统综述,检索Cochrane Library、Medline、Scopus和Web of Science数据库。
  • 纳入18项队列研究,共5307例患者,比较CT获得的HU值与DXA的T值对区域骨密度的预测。

主要发现

  • HU测量最常在L1进行(N=3;18.8%)。
  • 七项研究报告了按DXA骨密度分组的平均HU值:骨质疏松54.7至130,骨量减少78.8至146,正常120.8至230。
  • 八项研究通过ROC曲线确定骨质疏松诊断阈值,值范围为0.66至0.96。
  • 排除两项离群值论文后,报告为骨质疏松诊断的中位HU值在110至150之间。

关键数值与推荐

  • 推断诊断骨质疏松的HU区间为90.9至138.7(95%CI,P<0.001)。
  • 骨质疏松患者平均HU值范围为54.7至130(基于七项研究)。
  • 骨量减少患者平均HU值范围为78.8至146(基于七项研究)。
  • 正常患者平均HU值范围为120.8至230(基于七项研究)。

临床怎么用

  • 可利用腰椎CT测量的HU值辅助评估骨质量,对骨质疏松及脆性骨折风险患者进行分诊。
  • HU值可能有助于修改手术指征,但需结合DXA等标准评估。

局限性

  • 需要前瞻性大规模研究来更稳健地推断基于CT量化骨密度作为筛查试验的可能性及预后价值。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

STUDY DESIGN: Systematic review. OBJECTIVE: This work aimed to compare the Hounsfield units (HU) value obtained from computed tomography and the t score of dual-energy x-ray absorptiometry (DXA) in the prediction of the lumbar spine bone mineral density (BMD). SUMMARY OF BACKGROUND DATA: Several reports have found a correlation between HU and BMD values based on DXA. Using HUs to infer bone quality has a thorough clinical relevance as it could triage patients at risk for osteoporotic and fragility fractures or modify surgical indications. METHODS: A systematic review in Cochrane Library, Medline, Scopus and Web of Science was performed, using the following query: "hounsfield units" AND ("osteoporosis" OR "spine" OR "bone mineral density" OR "dual x-ray absorptiometry"). We included 18 cohort studies that compared HU value obtained from computed tomography and t score of DXA for predicting regional BMD. RESULTS: A total of 18 studies were included, enrolling 5307 patients. The HU measurement was most frequently made at L1 (N = 3; 18.8%). The mean HU values differentiated based on BMD measured through DXA were reported in seven studies, with values from 54.7 to 130 for osteoporotic, 78.8 to 146 for osteopenic, and from 120.8 to 230 in normal patients. Eight studies identified thresholds for diagnosing osteoporosis through receiver-operating characteristic (ROC) curves, with values ranging from 0.66 to 0.96. Medium HU values reported as diagnostic of osteoporosis ranged between 110 and 150, after exclusion of the two papers presenting outlier values. We infer an HU interval value of 90.9 to 138.7 (95% CI, P < 0.001) for the diagnosis osteoporosis. CONCLUSIONS: Present data evidence favorable results regarding the possibility of establishing a threshold value for osteoporosis diagnosis from CT measurements of HU. Prospective large-scale studies are needed to more robustly infer the possibility of quantifying BMD based on CT as a screening test and infer a prognostic value of the CT-based evaluation.Level of Evidence: 2.

来源:Spine (Phila Pa 1976),查看原文。版权归原作者所有。

引用

  1. Pinto EM, Neves JR, Teixeira A, et al. Efficacy of Hounsfield Units Measured by Lumbar Computer Tomography on Bone Density Assessment: A Systematic Review. Spine (Phila Pa 1976). 2021. PMID: 34468433. doi:10.1097/BRS.0000000000004211

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。