非对称交联聚乙烯内衬可降低全髋关节置换翻修风险:国家关节登记分析
本研究利用英国国家关节登记数据,分析非骨水泥型和混合型全髋关节置换(THA)中使用非对称交联聚乙烯内衬对翻修风险的影响。共纳入213,146例THA,记录2,997例翻修。结果显示,后路手术中使用非对称内衬可降低因不稳和任何原因导致的翻修风险;Hardinge/前外侧入路下非对称内衬亦与翻修风险降低相关,但对不稳翻修的影响较弱。
要点
- 后路THA使用非对称内衬较平内衬降低任何原因翻修风险(HR 1.122, 95%CI 1.108–1.346)。
- Hardinge/前外侧入路使用非对称内衬较平内衬降低任何原因翻修风险(HR 1.169, 95%CI 1.022–1.337)。
- 非对称内衬未增加任何手术入路的无菌性松动翻修风险。
核心结论
- 后路THA使用非对称内衬可降低因不稳和任何原因导致的翻修风险。
- Hardinge/前外侧入路THA使用非对称内衬与翻修风险降低相关,但对不稳翻修的影响弱于后路。
研究设计与样本
- 登记研究,结合国家关节登记数据集与制造商提供的聚乙烯生产特征。
- 共纳入213,146例非骨水泥型和混合型THA,主要终点为任何原因翻修,采用Cox比例风险回归分析。
主要发现
- 共记录2,997例翻修,其中平内衬THA 1,569例,非对称内衬THA 1,428例。
- Hardinge/前外侧入路下,平内衬较非对称内衬任何原因翻修HR为1.169(95%CI 1.022–1.337)。
- 后路下,平内衬较非对称内衬任何原因翻修HR为1.122(95%CI 1.108–1.346)。
- 仅分析平内衬THA时,Hardinge/前外侧入路较后路不稳翻修HR为0.561(95%CI 0.446–0.706)。
- 仅分析非对称内衬THA时,两种入路间不稳翻修风险无显著差异(HR 0.838, 95%CI 0.633–1.110)。
关键数值与推荐
- 后路THA中,非对称内衬较平内衬降低任何原因翻修风险(HR 1.122, 95%CI 1.108–1.346)。
- Hardinge/前外侧入路THA中,非对称内衬较平内衬降低任何原因翻修风险(HR 1.169, 95%CI 1.022–1.337)。
- 非对称内衬未增加任何手术入路的无菌性松动翻修风险。
临床怎么用
- 后路THA可优先考虑使用非对称交联聚乙烯内衬以降低不稳相关翻修风险。
- Hardinge/前外侧入路THA使用非对称内衬亦与翻修风险降低相关,但对其不稳翻修的影响较弱。
局限性
- 本研究为登记研究,可能存在未测量混杂因素。
- 聚乙烯生产特征由制造商提供,可能存在分类或报告偏倚。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: The aim of our study was to investigate the effect of asymmetric crosslinked polyethylene liner use on the risk of revision of cementless and hybrid total hip arthroplasties (THAs). METHODS: We undertook a registry study combining the National Joint Registry dataset with polyethylene manufacturing characteristics as supplied by the manufacturers. The primary endpoint was revision for any reason. We performed further analyses on other reasons including instability, aseptic loosening, wear, and liner dissociation. The primary analytic approach was Cox proportional hazard regression. RESULTS: A total of 213,146 THAs were included in the analysis. Overall, 2,997 revisions were recorded, 1,569 in THAs with a flat liner and 1,428 in THAs using an asymmetric liner. Flat liner THAs had a higher risk of revision for any reason than asymmetric liner THAs when implanted through a Hardinge/anterolateral approach (hazard ratio (HR) 1.169, 95% confidence interval (CI) 1.022 to 1.337) and through a posterior approach (HR 1.122, 95% CI 1.108 to 1.346). There was no increased risk of revision for aseptic loosening when asymmetric liners were used for any surgical approach. A separate analysis of the three most frequently used crosslinked polyethylene liners was in agreement with this finding. When analyzing THAs with flat liners only, THAs implanted through a Hardinge/anterolateral approach were associated with a reduced risk of revision for instability compared to posterior approach THAs (HR 0.561 (95% CI 0.446 to 0.706)). When analyzing THAs with an asymmetric liner, there was no significant difference in the risk of revision for instability between the two approaches (HR 0.838 (95% CI 0.633 to 1.110)). CONCLUSION: For THAs implanted through the posterior approach, the use of asymmetric liners reduces the risk of revision for instability and revision for any reason. In THAs implanted through a Hardinge/anterolateral approach, the use of an asymmetric liner was associated with a reduced risk of revision. The effect on revision for instability was less pronounced than in the posterior approach. Cite this article: Bone Joint J 2021;103-B(9):1479-1487.
引用
- Davis ET, Pagkalos J, Kopjar B, et al. Using an asymmetric crosslinked polyethylene liner in primary total hip arthroplasty is associated with a lower risk of revision surgery : an analysis of the National Joint Registry. Bone Joint J. 2021. PMID: 34465151. doi:10.1302/0301-620X.103B9.BJJ-2021-0365.R1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。