该病例对照研究比较了37例因外侧间室骨关节炎进展而翻修和61例因无菌性松动翻修的内侧固定平台单髁置换(UKA)与匹配的良好功能UKA的胫骨假体对线和下肢力线。结果显示翻修组胫骨假体对线与成功组相似,但下肢力线(HKA角)差异显著,多因素回归显示HKA角是与翻修最显著相关的因素。
要点
- 进展组HKA角较成功组更外翻(0.3°±3.6°外翻 vs 4.4°±2.6°内翻,P<.001)。
- 松动组HKA角较成功组更内翻(6.1°±3.1°内翻 vs 4.0°±2.7°内翻,P<.001)。
- 胫骨假体对线在翻修组与成功组间无显著差异,HKA角是与翻修最显著相关的因素。
核心结论
- 在下肢力线和胫骨假体对线中,下肢力线是UKA结局更重要的决定因素。
研究设计与样本
- 病例对照研究(证据等级III),从2000年以来3351例内侧固定平台UKA的前瞻性机构数据库中识别37例因进展翻修和61例因松动翻修,并与最小10年随访、KSS≥70的成功UKA按年龄、性别、BMI和术后活动度匹配。
主要发现
- 进展组胫骨假体冠状面对线为3.6°±3.5°内翻,成功组为5.1°±3.5°内翻(P=.07);矢状面对线分别为8.4°±4.4°和8.8°±3.6°(P=.67)。
- 进展组HKA角为0.3°±3.6°外翻,成功组为4.4°±2.6°内翻(P<.001)。
- 松动组胫骨假体冠状面对线为6.1°±3.7°内翻,成功组为5.9°±3.1°内翻(P=.72);矢状面对线分别为8.4°±4.6°和8.1°±3.9°(P=.68)。
- 松动组HKA角为6.1°±3.1°内翻,成功组为4.0°±2.7°内翻(P<.001)。
- 多因素logistic回归显示HKA角是与翻修最显著相关的因素(P<.001)。
临床怎么用
- 在UKA术后评估中应重视下肢整体力线(HKA角),而不仅关注胫骨假体对线。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: To assess how implant alignment affects unicompartmental knee arthroplasty (UKA) outcome, we compared tibial component alignment of well-functioning UKAs against 2 groups of failed UKAs, revised for progression of lateral compartment arthritis ("Progression") and aseptic loosening ("Loosening"). METHODS: We identified 37 revisions for Progression and 61 revisions for Loosening from our prospective institutional database of 3351 medial fixed-bearing UKAs performed since 2000. Revision cohorts were matched on age, gender, body mass index, and postoperative range of motion with "Successful" unrevised UKAs with minimum 10-year follow-up and Knee Society Score ≥70. Tibial component coronal (TCA) and sagittal (TSA) plane alignment was measured on postoperative radiographs. Limb alignment was quantified by hip-knee-ankle (HKA) angle on long-leg radiographs. In addition to directly comparing groups, a multivariate logistic regression examined how limb and component alignments were associated with UKA revision. RESULTS: In the Progression group, component alignment was similar to the matched successes (TCA 3.6° ± 3.5° varus vs 5.1° ± 3.5° varus, P = .07; TSA 8.4° ± 4.4° vs 8.8° ± 3.6°, P = .67), whereas HKA angle was significantly more valgus (0.3° ± 3.6° valgus vs 4.4° ± 2.6° varus, P < .001). Loosening group component alignment was also similar to the matched successes (TCA 6.1° ± 3.7° varus vs 5.9° ± 3.1° varus, P = .72; TSA 8.4° ± 4.6° vs 8.1° ± 3.9°, P = .68), and HKA was significantly more varus (6.1° ± 3.1° varus vs 4.0° ± 2.7° varus, P < .001). Using a multivariate logistic regression, HKA angle was the most significant factor associated with revision (P < .001). CONCLUSION: In this population of revised UKAs and long-term successes, limb alignment was a more important determinant of outcome than tibial component alignment. LEVEL OF EVIDENCE: Level III case-control study.
引用
- Slaven SE, Cody JP, Sershon RA, et al. Alignment in Medial Fixed-Bearing Unicompartmental Knee Arthroplasty: The Limb Has a Leg Up on the Component. J Arthroplasty. 2021. PMID: 34489145. doi:10.1016/j.arth.2021.08.015
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。