PubMed 文献 · Spine (Phila Pa 1976) · 2021-09-20

回顾性观察研究纳入58例儿童脊柱侧凸患者共855枚椎弓根螺钉,比较术中锥形束CT正常剂量与低剂量(正常剂量的1/3或1/5)下螺钉穿破率。结果显示两组穿破率相当(1.8% vs 1.7%),距上端固定椎距离和患者较矮身材与穿破独立相关。

要点

  • 低剂量术中CBCT导航未增加椎弓根螺钉穿破率。
  • 距上端固定椎越近,螺钉穿破风险越高。
  • 身材较矮患者螺钉穿破风险更高,需额外注意。

核心结论

  • 降低术中导航CBCT辐射剂量未增加椎弓根螺钉穿破率,但靠近上端固定椎的椎体和身材较矮患者需额外小心。

研究设计与样本

  • 回顾性观察研究,纳入58例儿童脊柱侧凸患者(11男47女,平均年龄16.6岁),共评估855枚椎弓根螺钉,低剂量定义为正常剂量的1/3或1/5。

主要发现

  • 正常剂量组567枚螺钉穿破率为1.8%,低剂量组288枚螺钉穿破率为1.7%,两组相当。
  • 多因素logistic回归显示距上端固定椎距离是螺钉穿破的独立相关因素(每增加1个椎体,OR 0.73,P=0.038)。
  • 有穿破患者平均身高148.8±3.6 cm显著短于无穿破患者157.9±1.2 cm(P=0.034)。

关键数值与推荐

  • 穿破定义为G2-3级,即穿破4 mm或以上。

临床怎么用

  • 儿童脊柱侧凸后路融合术中可使用低剂量CBCT导航以减少辐射,同时关注靠近上端固定椎的椎体和身材较矮患者。

局限性

  • 回顾性观察研究,证据等级为3级。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

STUDY DESIGN: Retrospective observational study. OBJECTIVE: This study aimed to determine the effect of reducing the radiation dose of intraoperative cone beam computed tomography (CBCT) during posterior spinal fusion (PSF) for pediatric scoliosis on the rate of pedicle screw (PS) violation. SUMMARY OF BACKGROUND DATA: Intraoperative CBCT for pediatric scoliosis improves the accuracy of PS insertion in PSF. However, few reports have addressed the PS perforation rate from reduced radiation doses in hybrid navigation. METHODS: We evaluated 855 PSs inserted into 58 pediatric scoliosis patients (11 male and 47 female, mean age: 16.6 yr) who underwent PSF using CBCT. A radiation dose of 1/3 or 1/5 of the normal dose (ND) was defined as a low dose (LD). After PS insertion, intraoperative CBCT images were reviewed to assess the degree of PS perforation. G2-3 (i.e., perforations of 4 mm or more) was defined as a violation. The PS violation rate was compared between the groups, and factors associated with violations were examined. RESULTS: A total of 567 and 288 screws were inserted in the ND group and LD group, respectively. The PS violation rate was comparable at 1.8% in the ND group and 1.7% in the LD group. Multiple logistic regression analysis showed that distance from the upper instrumented vertebra (UIV) was an independently associated factor of PS violation (+1 vertebra, operation room 0.73, P = 0.038). In addition, the mean height of patients with PS violations (148.8 ± 3.6 cm) was significantly shorter than that of patients without violations (157.9 ± 1.2 cm) ( P = 0.034). CONCLUSION: There was no increase in PS violation rate with lower doses of radiation for intraoperative navigation CBCT. Extra care is warranted for vertebrae close to the UIV and patients of shorter stature.Level of Evidence: 3.

来源:Spine (Phila Pa 1976),查看原文。版权归原作者所有。

引用

  1. Tanikawa Y, Oba H, Fujii M, et al. Intraoperative Cone Beam CT in Hybrid Operation Room for Pediatric Scoliosis Patients: Comparison of Pedicle Screw Violation Rate at Normal and Low Radiation Doses. Spine (Phila Pa 1976). 2021. PMID: 34545047. doi:10.1097/BRS.0000000000004226