3D打印矫形器治疗青少年特发性脊柱侧凸的随机对照试验
结果显示两组即刻矫形效果相当,生活质量评估无显著差异,2年随访时角度变化和佩戴依从性亦无显著差异。
要点
- 3D打印矫形器与常规矫形器在即刻矫形效果上相当。
- 两组生活质量评估无显著差异。
- 2年随访时两组角度变化和佩戴时长无显著差异。
核心结论
- 3D打印矫形器可提供与常规矫形器相当的临床效果,且依从性和生活质量相似。
主要发现
- 3D打印矫形器组即刻矫形角度变化为-11.6°(P<0.001),常规矫形器组为-12.9°(P<0.001)。
- 3D打印矫形器组在3个月时功能、自我形象和心理健康方面评分变差(-0.5、-0.6、-0.7,P<0.05),常规矫形器组在自我形象和心理健康方面变差(-0.3、-0.3,P<0.05)。
- 2年随访时22例患者完成分析,两组角度变化相当(3D打印组:-2.2°,P=0.364;常规组:-3.5°,P=0.193)。
- 3D打印矫形器组有1例(9.1%)曲线进展>5°,常规矫形器组有2例(18.2%)。
- 3D打印矫形器组每日佩戴时间比常规矫形器组长1.9小时(17.1 vs. 15.2小时,P=0.934)。
临床怎么用
- 3D打印矫形器可作为青少年特发性脊柱侧凸管理的可选方案,临床效果与常规矫形器相当。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
STUDY DESIGN: Prospective randomized controlled trial. OBJECTIVE: To compare clinical effectiveness and quality of life (QoL) of the 3D-printed orthosis (3O) and conventional orthosis (CO) for adolescent idiopathic scoliosis (AIS). SUMMARY OF BACKGROUND DATA: Using 3D printing technology to design and fabricate orthoses to manage AIS aiming to improve in-orthosis correction and patients' compliance that are considered essential factors of effective treatment. Clinical evaluation was conducted to study the effectiveness of this innovative method. METHODS: Thirty females with AIS who met the criteria (age 10-14, Cobb 20-40°, Risser sign 0-2, ≤12 months after menarche) were recruited. Subjects were randomly allocated to the 3O group (n = 15, age 12.4, Cobb 31.8°) and CO group (n = 15, age 12.0, Cobb 29.3°). All patients were prescribed for full-time wearing (23 hours/d) and follow-up every 4 to 6 months until bone maturity. Compliance was monitored by thermosensors, while QoL was assessed using three validated questionnaires. RESULTS: Comparable immediate in-orthosis correction was observed between 3O (-11.6°, P < 0.001) and CO groups (-12.9°, P < 0.001). In the QoL study via SRS-22r, the 3O group got worse results after 3 months in aspects of function, self-image, and mental health (-0.5, -0.6, -0.7, P < 0.05) while the CO group had worse results in aspects of self-image and mental health (-0.3, -0.3, P < 0.05). No significant difference was found in QoL assessments between groups. After 2 years of follow-up, 22 patients were analyzed with 4 dropouts in each group. Comparable angle reduction was observed in both groups (3O: -2.2°, P = 0.364; CO: -3.5°, P = 0.193). There was one subject (9.1%) in the 3O group while two subjects (18.2%) in the CO group had curve progression >5°. Daily wearing hours were 1.9 hours longer in the 3O group than the CO group (17.1 vs. 15.2 hours, P = 0.934). CONCLUSION: The 3O group could provide comparable clinical effects as compared with the CO group while patients with 3O showed similar compliance and QoL compared to those with CO.Level of Evidence: 1.
引用
- Lin Y, Cheung JPY, Chan CK, et al. A Randomized Controlled Trial to Evaluate the Clinical Effectiveness of 3D-Printed Orthosis in the Management of Adolescent Idiopathic Scoliosis. Spine (Phila Pa 1976). 2022. PMID: 34392277. doi:10.1097/BRS.0000000000004202
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。