文献速递关节外科

前入路置入无领抛光锥形股骨柄的骨水泥层质量与假体对线评估

Cementing a collarless polished tapered femoral stem through the anterior approach : evaluation of cement mantle quality and component alignment.
PubMed 文献 · Bone Joint J · 2021-01-01

本研究回顾性比较了115例经前入路或后入路置入无领抛光锥形骨水泥股骨柄的髋关节置换病例,放射学评估骨水泥层质量和假体对线。结果显示两组在Barrack分级和对线方面无显著差异,前入路可获得足够的骨水泥层和良好的对线。

要点

  • 前入路与后入路在骨水泥层Barrack分级和对线方面无显著差异。
  • 前入路组Barrack A或B级占77.6%,后入路组占86%。
  • 较高BMI、左侧和Dorr C型形态与不满意的骨水泥层相关。

核心结论

  • 经前入路置入无领抛光锥形股骨柄可获得足够的骨水泥层和良好的假体对线。

研究设计与样本

  • 回顾性比较研究,纳入115例连续混合全髋关节置换或骨水泥半髋置换术,前入路58例,后入路57例,使用无领抛光锥形滑配股骨柄。

主要发现

  • 两组在正位和侧位Barrack分级及对线方面无显著差异(正位Barrack p=0.640,侧位Barrack p=0.306;正位对线p=0.603,侧位对线p=0.254)。
  • 前入路组Barrack A或B级占77.6%(n=45),后入路组占86%(n=49)。
  • 多因素分析显示较高BMI、左侧和Dorr C型形态与不满意骨水泥层(Barrack C或D)相关。
  • 两种入路在所有Gruen区平均骨水泥层厚度均≥2 mm;前入路组7区平均骨水泥层更厚(p<0.001),9区更薄(p=0.032)。
  • 两组骨水泥层缺损发生率相似(6.9%(n=4)vs 8.8%(n=5),p=0.489)。

临床怎么用

  • 前入路可用于置入无领抛光锥形骨水泥股骨柄,骨水泥层质量和假体对线可接受。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: The aim of this study was to radiologically evaluate the quality of cement mantle and alignment achieved with a polished tapered cemented femoral stem inserted through the anterior approach and compared with the posterior approach. METHODS: A comparative retrospective study of 115 consecutive hybrid total hip arthroplasties or cemented hemiarthroplasties in 110 patients, performed through anterior (n = 58) or posterior approach (n = 57) using a collarless polished taper-slip femoral stem, was conducted. Cement mantle quality and thickness were assessed in both planes. Radiological outcomes were compared between groups. RESULTS: No significant differences were identified between groups in Barrack grade on the anteroposterior (AP) (p = 0.640) or lateral views (p = 0.306), or for alignment on the AP (p = 0.603) or lateral views (p = 0.254). An adequate cement mantle (Barrack A or B) was achieved in 77.6% (anterior group, n = 45) and in 86% (posterior group, n = 49), respectively. Multivariate analysis revealed factors associated with unsatisfactory cement mantle (Barrack C or D) included higher BMI, left side, and Dorr Type C morphology. A mean cement mantle thickness of ≥ 2 mm was achieved in all Gruen zones for both approaches. The mean cement mantle was thicker in zone 7 (p < 0.001) and thinner in zone 9 for the anterior approach (p = 0.032). Incidence of cement mantle defects between groups was similar (6.9% (n = 4) vs 8.8% (n = 5), respectively; p = 0.489). CONCLUSION: An adequate cement mantle and good alignment can be achieved using a collarless polished tapered femoral component inserted through the anterior approach. Cite this article: Bone Joint J 2021;103-B(7 Supple B):46-52.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. McGoldrick NP, Fischman D, Nicol GM, et al. Cementing a collarless polished tapered femoral stem through the anterior approach : evaluation of cement mantle quality and component alignment. Bone Joint J. 2021. PMID: 34192917. doi:10.1302/0301-620X.103B7.BJJ-2020-2394.R1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。