翻修全髋关节置换中模块化双动髋臼组件的中期随访问题
本研究回顾性分析了单中心94例翻修全髋关节置换(THA)使用模块化双动(MDM)髋臼组件的患者,平均随访5.5年。结果显示脱位率为11%,6年无脱位生存率91%;外头直径≥48 mm与脱位风险降低相关(p=0.013),腰骶融合与脱位增加相关(p=0.004);无菌性髋臼松动翻修率低(4%),但感染再翻修率为15%。
要点
- MDM组件在翻修THA中脱位率11%,高于既往报道。
- 外头直径≥48 mm与脱位风险降低相关(p=0.013)。
- 腰骶融合与脱位风险增加相关(p=0.004)。
核心结论
- 使用该MDM组件行翻修THA,平均随访5.5年时脱位率为11%,高于既往报道。
- 外头尺寸与脱位风险相关,无菌性髋臼松动率低。
- 需要更长随访并评估其他设计。
研究设计与样本
- 单中心回顾性队列研究,纳入94例翻修THA(88例患者),使用单一设计MDM髋臼组件,平均随访5.5年。
主要发现
- 总体脱位率为11%,6年生存率为91%。
- 因脱位再手术7例(7%),6年生存率为94%。
- 脱位早期6例(平均33天),晚期4例(平均4.3年),假体内分离3例。
- 外头直径≥48 mm与脱位风险降低相关(p=0.013),腰骶融合与脱位增加相关(p=0.004)。
- 4例(4%)因无菌性髋臼松动再翻修,初次翻修时严重骨缺损(Paprosky III)与再翻修显著相关(p=0.008)。
关键数值与推荐
- 脱位率11%,6年无脱位生存率91%。
- 因脱位再手术率7%,6年生存率94%。
- 无菌性髋臼松动再翻修率4%,Paprosky III骨缺损与再翻修相关(p=0.008)。
- 感染再翻修率15%,术前诊断为假体周围感染(PJI)后再植入与后续PJI相关(p<0.001)。
- 2例THA可见钴铬内衬背侧金属改变。
临床怎么用
- 翻修THA使用MDM组件时需注意脱位风险,尤其对于腰骶融合患者。
- 选择外头直径≥48 mm可能降低脱位风险。
- 严重骨缺损(Paprosky III)患者需警惕无菌性松动再翻修。
- 术前PJI后再植入患者需警惕后续感染。
局限性
- 回顾性单中心研究,样本量有限。
- 仅评估单一MDM设计,随访时间中期。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: Modular dual mobility (MDM) acetabular components are often used with the aim of reducing the risk of dislocation in revision total hip arthroplasty (THA). There is, however, little information in the literature about its use in this context. The aim of this study, therefore, was to evaluate the outcomes in a cohort of patients in whom MDM components were used at revision THA, with a mean follow-up of more than five years. METHODS: Using the database of a single academic centre, 126 revision THAs in 117 patients using a single design of an MDM acetabular component were retrospectively reviewed. A total of 94 revision THAs in 88 patients with a mean follow-up of 5.5 years were included in the study. Survivorship was analyzed with the endpoints of dislocation, reoperation for dislocation, acetabular revision for aseptic loosening, and acetabular revision for any reason. The secondary endpoints were surgical complications and the radiological outcome. RESULTS: The overall rate of dislocation was 11%, with a six-year survival of 91%. Reoperation for dislocation was performed in seven patients (7%), with a six-year survival of 94%. The dislocations were early (at a mean of 33 days) in six patients, and late (at a mean of 4.3 years) in four patients. There were three intraprosthetic dissociations. An outer head diameter of ≥ 48 mm was associated with a lower risk of dislocation (p = 0.013). Lumbrosacral fusion was associated with increased dislocation (p = 0.004). Four revision THAs (4%) were further revised for aseptic acetabular loosening, and severe bone loss (Paprosky III) at the time of the initial revision was significantly associated with further revision for aseptic acetabular loosening (p = 0.008). Fourteen acetabular components (15%) were re-revised for infection, and a pre-revision diagnosis of reimplantation after periprosthetic joint infection (PJI) was associated with subsequent PJI (p < 0.001). Two THAs had visible metallic changes on the backside of the cobalt chromium liner. CONCLUSION: When using this MDM component in revision THA, at a mean follow-up of 5.5 years, there was a higher rate of dislocation (11%) than previously reported. The size of the outer bearing was related to the risk of dislocation. There was a low rate of aseptic acetabular loosening. Longer follow-up of this MDM component and evaluation of other designs are warranted. Cite this article: Bone Joint J 2021;103-B(7 Supple B):66-72.
引用
- Hernandez NM, Hinton ZW, Wu CJ, et al. Is there a problem with modular dual mobility acetabular components in revision total hip arthroplasty at mid-term follow-up? Bone Joint J. 2021. PMID: 34192910. doi:10.1302/0301-620X.103B7.BJJ-2020-2015.R1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。